PMC Alarm Diagnostics for ISD/PMC and PMC Only Configurations VP EMISSIONS
29
VP EMISSIONS
The effluent emissions concentration test occurs at daily intervals at the daily assessment time after at least one
day's HC%, processor run time and station throughput has been collected. A failure occurs when the mass
emission exceeds the defined threshold for the system. A failure of the effluent emissions concentration test will
result in a warning and warning event recording. Two consecutive 1-day periods of effluent emissions
concentration test failures will result in a failure alarm, failure event recording, and shutdown of the site. The
processor is not allowed to operate while the emission FAILURE is active
ISD MONITORING CATEGORY
Vapor Processor Monitoring is responsible for ensuring that the vapor processor is operating within normal
parameters.
DIAGNOSTIC PROCEDURE
• Refer problem to the processor manufacturer certified technician.
• Refer to the Clear Test Repair Menu (on page 36) for clearing this alarm on the TLS after repairs are complete.
COMMON CAUSES
• The processor is hydrocarbon emissions are exceeding defined limits.
FIELD NOTES
• This warning will not appear on a Healy EVR system.