EasyManuals Logo
Home>Veeder-Root>Measuring Instruments>TLS2

Veeder-Root TLS2 Serial Interface Manual

Veeder-Root TLS2
165 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #141 background imageLoading...
Page #141 background image
Serial Interface Manual
TLS2 Monitoring Systems
Part No. 577013-767, Revision H 138
Function Code 905 Notes: (Continued)
9. nn - number of 2 byte values to follow (Hex)
10. AA - PERIODIC IN-TANK TESTS (00 = DISABLE, 01 = ENABLE)
11. BB - ANNUAL IN-TANK TESTS (00 = DISABLE, 01 = ENABLE)
12. CC - CSLD (00 = DISABLE, 01 = ENABLE)
13. DD - BIR (00 = DISABLE, 01 = ENABLE)
14. EE - FUEL MANAGER (00 = DISABLE, 01 = ENABLE)
15. FF - PRECISION PLLD (00 = DISABLE, 01 = ENABLE)
16. GG - TANKER LOAD (00 = DISABLE, 01 = ENABLE)
17. HH - 0.2 GPH PLLD (00 = DISABLE, 01 = ENABLE)
18. II - PRECISION PLLD ON DEMAND (00 = DISABLE, 01 = ENABLE)
19. JJ - SPECIAL 3-TANK/LINE CONSOLE (00 = DISABLE, 01 = ENABLE)
20. nnnnnn-vvv-r - SEM Info 3 parts, if none "NO SOFTWARE MODULE"
21. nnnnnn - SEM number (ASCII text string)
22. vvv - SEM Software version number (ASCII text string)
23. r - SEM Software revision level (ASCII text string)
24. && - Data Termination Flag
25. CCCC - Message Checksum

Other manuals for Veeder-Root TLS2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Veeder-Root TLS2 and is the answer not in the manual?

Veeder-Root TLS2 Specifications

General IconGeneral
BrandVeeder-Root
ModelTLS2
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals