7.4.2 IN-TANK DIAGNOSTIC REPORTS
Function Code:
A01 Version 1
Function Type: Probe Type and Serial Number
Command Format:
Display: <SOH>IA01TT
Computer: <SOH>iA01TT
Typical Response Message, Display Format:
<SOH>
IA0101
22-05-01 15:12
TYPE CODE LENGTH SERIAL NO. D/CODE OPT
TANK 1 REGULAR UNLEADED MAG C001 96.00 123001 0000 0x0000
<ETX>
Typical Response Message, Computer Format:
<SOH>iA01TTYYMMDDHHmmTTpPPKKKKFFFFFFFFSSSSSScccc
TTpPPKKKKFFFFFFFFSSSSSScccc&&CCCC<ETX>
Notes:
1. YYMMDDHHmm - Current Date and Time
2. TT - Tank Number (Decimal, 00 = all)
3. p - Product Code (single ASCII character, from 20 Hex - 7E Hex)
4. PP - Probe Type:
00 - Unknown (no further data follows for this probe)
03 - MAG
5. KKKK - Circuit Code (Hex)
6. FFFFFFFF - Probe Length (ASCII Hex IEEE float)
7. SSSSSS - Probe Serial Number (Decimal)
8. cccc - Probe Date Code (Hex)
9. && - Data Termination Flag
10. CCCC - Message Checksum