7.3.3 I/O DEVICE SETUP
Function Code:
55C Version 1
Function Type: Set Relay Alarm Assignment
Command Format: Inquire:
Display: <SOH>S55C00M <SOH>I55C00
Computer: <SOH>s55C00M <SOH>i55C00
Typical Response Message, Display Format:
<SOH>
I55C01
22-05-01 15:06
ALARM RELAY : NONE
<ETX>
Typical Response Message, Computer Format:
<SOH>i55C00YYMMDDHHmmM&&CCCC<ETX>
Notes:
1. YYMMDDHHmm - Current Date and Time
2. M - Relay mode:
0 = None
1 = Overfill
2 = Any Alarm
3. && - Data Termination Flag
4. CCCC - Message Checksum