EasyManua.ls Logo

Veeder-Root TLS2 - Page 150

Veeder-Root TLS2
165 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Serial Interface Manual
TLS2 Monitoring Systems
Part No. 577013-767, Revision H 147
Function Code: A18 Version 4
Function Type: Probe Diagnostic Printout
Command Format:
Display: <SOH>IA18TT
Computer: <SOH>iA18TT
Typical Response Message, Display Format:
<SOH>
IA1801
22-05-01 15:13
DIAGNOSTICS
SOFTWARE REVISION 349783-001-B
TANK : 1
PROBE TYPE : MAG1
SERIAL NUMBER : 168809
PROBE ID : 0XC000
PROBE LENGTH : 30.00
GRADIENT : 354.520
NUMBER SAMPLES : 20
SAMPLES READ : 47357
SAMPLES USED : 47348
REF DISTANCE : 08-21-08 102.00
08-27-08 102.00
TEMP 6 : 72.6
TEMP 5 : 72.1
TEMP 4 : 70.9
TEMP 3 : 69.4
TEMP 2 : 68.3
TEMP 1 : 67.6
TEMP 6 TEMP 5 : 0.5
TEMP 5 TEMP 4 : 1.3
TEMP 4 TEMP 3 : 1.5
TEMP 3 TEMP 2 : 1.1
TEMP 2 TEMP 1 : 0.7
COUNTS 00 : 001319
COUNTS 01 : 007412
COUNTS 02 : 007412
COUNTS 03 : 007412
COUNTS 04 : 007412
COUNTS 05 : 007412
COUNTS 06 : 007412
COUNTS 07 : 007412
COUNTS 08 : 007412
COUNTS 09 : 007412
COUNTS 10 : 007412
COUNTS 11 : 044368
COUNTS 12 : 016952
COUNTS 13 : 017295
COUNTS 14 : 017435

Other manuals for Veeder-Root TLS2