Serial Interface Manual
TLS2 Monitoring Systems
Part No. 577013-767, Revision H 16
Function Code 101 Notes: (Continued)
Typical Response Message, Computer Format:
<SOH>i10100YYMMDDHHmmAANNTT...
AANNTT&&CCCC<ETX>
Notes:
1. YYMMDDHHmm - Current Date and Time
2. AA - Alarm/Warning Category:
00 - All Functions Normal
02 - Tank Alarm
14 - Auto-Dial Fax Alarm
3. NN - Alarm Type Number:
- If AA is 02 and NN is:
03 = Tank High Water Alarm
04 = Tank Overfill Alarm
05 = Tank Low Product Alarm
08 = Tank Invalid Fuel Level Alarm
09 = Tank Probe Out Alarm
11 = Tank Delivery Needed Warning
12 = Tank Maximum Product Alarm
13 = Tank Gross Leak Test Fail Alarm
14 = Tank Periodic Leak Test Fail Alarm
15 = Tank Annual Leak Test Fail Alarm
27 = Tank Cold Temperature Warning
- If AA is 14 and NN is:
02 = Autodial Failed Alarm
4. TT - Tank/Sensor Number
5. && - Data Termination Flag
6. CCCC - Message Checksum