Overvoltage
protection unit
mounted on
oscillator
Oscillator
CB
2-36
CAP
E32(H)EX
Vessel
Zone 0
Oscillator
Li=0,12 mH
Ci=6 nF
External earth terminal
Internal earth terminal
Vessel
Zone 0
CAP
E32
(H)Ex
External earth terminal
Internal earth terminal
Li, Ci of the oscillator with
overvoltage protection unit
Li = 0,27 mH
Ci = 8,5 nF
(Ex)-area Zone 1
Not (Ex)-area
Signal
cond.
instr.
or
safety
barrier
Control room
either:
Overvoltage
protection unit
Type B62-36G
Li=0,15 mH
Ci=2,5 nF
Overvoltage protection unit
Type
B62-36G
Li=0,15 mH
Ci=2,5 nF
Isolated line
min. 4 mm
2
*
**
Screen
Between control room and overvoltage
protection system a suitable cable, if
necessary a metal cover or screen, must be
used. Metal cover or screen - if necessary -
must only be connected to earth or PA on
one line end.
Test voltage of the cable A: ≥ 500 V AC
Between overvoltage protection system
and capacitive electrode a suitable cable
with metal cover, screen or a suitable cable
with metal protection tube must be used
(metal cover or protection tube must be
connected with the potential equalisation).
Test voltage of the cable B: ≥ 1500 V AC
A
B
Overvoltage arrester type
B62-36 G in metal or plastic
housing
**
to potential
equalization line
Screen
to potential
equalization line
b)Capacitive electrodes with external
overvoltage protection unit
a) Capacitive electrodes with integral
overvoltage protection unit type CB 2-36
*
* either
screen only connected on one
line end to earth or PA
** either
screen only connected on one
line end with earth or PA