Operating Instructions
Radiometric sensor for density
measurement
MINITRAC 31
Foundation Fieldbus
Document ID: 41782

Table of Contents

Other manuals for Vega MINITRAC 31

Question and Answer IconNeed help?

Do you have a question about the Vega MINITRAC 31 and is the answer not in the manual?

Vega MINITRAC 31 Specifications

General IconGeneral
Measurement principleRadar
Frequency range80 GHz
Accuracy±2 mm
Process fitting1" NPT
Protection classIP67
Communication4 ... 20 mA/HART
Process temperature-40 to 200 °C

Summary

1 About this document

1.1 Function

Provides information for mounting, connection, setup, maintenance, and safety of the instrument.

1.2 Target group

Manual is directed to trained personnel and must be made available to qualified personnel.

1.3 Symbols used

Explanation of symbols used in the manual for clarity and safety.

2 For your safety

2.1 Authorised personnel

Operations must be performed only by trained, qualified, and authorized personnel wearing required PPE.

2.2 Appropriate use

Instrument is for density and level detection; operational reliability depends on proper usage.

2.3 Warning about incorrect use

Inappropriate use may cause hazards, damage, or contamination, impairing protective characteristics.

2.4 General safety instructions

Instrument must be operated in flawless condition; observe safety instructions, national standards, and regulations.

2.5 EU conformity

Device fulfills EU directives; CE marking confirms conformity. Includes EMC considerations for industrial environments.

2.6 NAMUR recommendations

Lists fulfilled NAMUR recommendations relevant to field instrumentation.

2.8 Environmental instructions

Emphasizes environmental protection and observation of packaging and disposal instructions.

3 Product description

3.1 Configuration

Explains the type label data for instrument identification and use.

3.2 Principle of operation

Detects density via gamma rays contactless through vessel wall; reliable in extreme conditions.

3.3 Packaging, transport and storage

Details packaging material, transport considerations, inspection, and storage conditions.

3.4 Accessories

Lists accessories such as PLICSCOM, VEGADIS 81, and electronics modules.

3.5 Corresponding source container

Prerequisite for radiometric measurement; handling of radioactive substances is regulated by law.

General instructions for radiation protection

Measures for protection against radiation: Shielding, Time, and Distance.

4 Mounting

4.1 General instructions

Source container must be locked; protect against moisture; observe process conditions.

4.2 Mounting instructions

Analyzes measurement loop conditions for isotope dimensioning; follow 'Source Sizing' document.

Density measurement

Density/concentration measurement on pipelines/vessels; accuracy increases with radiated length.

Mass flow rate

Mass flow rate determined with MINITRAC 31 in conjunction with a flow meter.

Point level detection

Sensor mounted horizontally at requested limit level; avoid struts/reinforcements.

Level measurement - Residue detection

Used for residue detection in tanks; mount at the lowest point of the vessel.

Protection against heat

Measures to protect against overheating: insulation, mounting away from heat source, cooling systems.

5 Connecting to power supply

5.1 Preparing the connection

Safety instructions for electrical connection; use disconnecting device; connect ground conductor.

5.2 Connection - Density, mass flow rate measurement

Details connection for density and mass flow rate measurement.

5.3 Connection - Level detection

Details connection for level detection.

Instruments with intrinsically safe signal output

Information on Ex-protected versions and specific safety instructions.

6 Set up with the display and adjustment module

6.1 Insert display and adjustment module

Steps to mount and dismount the display and adjustment module without interrupting voltage supply.

6.2 Adjustment system

Explains the display and adjustment elements, key functions, and time functions.

6.3 Parameter adjustment - Level measurement

Adapting the instrument to application conditions for level measurement.

6.4 Parameter adjustment - Density measurement

Adapting the instrument to application conditions for density measurement.

6.5 Parameter adjustment - Point level detection

Adapting the instrument to application conditions for point level detection.

6.6 Parameter adjustment - X-ray alarm

Adjusting the instrument to recognize and react to X-ray radiation.

6.7 Parameter adjustment - Real value correction

Correcting level measurement by resetting to the correct real value, e.g., due to buildup.

6.8 Saving the parameterisation data

Recommends documenting or saving data via PACTware or the adjustment module.

7 Setup with PACTware

7.1 Connect the PC

Connecting the PC to the sensor via the interface adapter VEGACONNECT.

7.2 Parameter adjustment with PACTware

Details on using PACTware for sensor adjustment, including software and DTM requirements.

7.3 Saving the parameterisation data

Recommends saving parameterisation data via PACTware for multiple uses or service purposes.

8 Set up with other systems

8.1 DD adjustment programs

Device descriptions for adjustment programs like AMS and PDM.

8.2 Field Communicator 375, 475

Device descriptions for parameterization using Field Communicator 375 or 475.

9 Diagnostics and servicing

9.1 Maintenance

No special maintenance required for normal operation; check source container regularly.

9.2 Status messages

Instrument features self-monitoring and diagnostics according to NE 107 and VDI/VDE 2650.

9.3 Rectify faults

Operator responsibility for fault rectification; includes basic measures and PC diagnosis.

9.4 Exchanging the electronics module

Procedure for replacing a defective electronics module by the user.

9.5 Software update

Components and procedure required for updating the instrument software.

9.6 How to proceed if a repair is necessary

Procedure for returning the sensor for repair, including documentation and packaging.

10 Dismount

10.1 Dismounting steps

Warning about process conditions before dismounting; carry out steps in reverse order.

10.2 Disposal

Instrument consists of recyclable materials; considerations for WEEE directive.

11 Supplement

11.1 Technical data

Technical data for approved instruments, including general data, materials, weight, and input variables.

11.2 Device communication Foundation Fieldbus

Device-specific details and characteristics for Foundation Fieldbus communication.

11.3 Dimensions

Dimensional drawings are available for download from the VEGA website.

11.4 Industrial property rights

Information on global protection of VEGA product lines by industrial property rights.

11.5 Trademark

Brands and company names used are property of their lawful proprietor/originator.

Related product manuals