T-9
04/2005
ERROR DESCRIPTION OF
ERROR CODE
CHECKING METHOD CORRECTIVE ACTION
Ram Error Ram check sum for service
mode settings stored in non-
volatile memory has been
corrupted.
No test available. If error shows up frequently, replace the control board.
AC Low AC voltage to the controller
is less than 20V
rms for more
than 30 seconds.
Check for low voltage at the wall outlet at unit start-up. Contact a qualified electrician.
Scale Scaling Factor error - one
of the credit peripherals has
introduced a scaling factor
that is not compatible with the
current configuration.
Check the connections of changer harness; make sure changer is
plugged in and working.
Make corrections to harness or replace the changer if necessary.
Inlet Sensor Machine’
s coin inlet sensor
is blocked for more than 1
minute.
Check changer harnessing for cut, pinched or crimped wires. Replace harnesses or changer.
Escrow Return Mech. 3 successive coins are
detected at the inlet but do
not make it into the changer
in 10 seconds.
Check inlet for blockage. If nothing is found, check changer
harnessing for cut, pinched or crimped wires.
Clear blockage or replace harness or changer
.