EasyManua.ls Logo

Vernacare COMPACT+ User Manual

Vernacare COMPACT+
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Vernacare COMPACT+ and is the answer not in the manual?

Vernacare COMPACT+ Specifications

General IconGeneral
BrandVernacare
ModelCOMPACT+
CategoryGarbage Disposal
LanguageEnglish

Summary

Warranty Information

Product Specifications

Electrical Specifications

Outlines electrical requirements, including voltage, current, fuses, and circuit protection.

Detailed Specifications

General Description and Operation

Safety Control Functions

Details safety systems preventing motor operation with an open lid and other hazards.

Installation and Commissioning

Plumbing Requirements

Electrical Connections and Safety

Single-Phase Electrical System

Specifies electrical system requirements for 230V and 110V machines, including protection.

Commissioning Procedure

Warning Labels and Icons

Display Screen Icons and Warnings

Subassemblies and Spare Parts

Sensor Arrangement Details

Air and Water Distribution Diagram

Engineer Mode Functions

Auto Start and Cycle Mode Settings

Fault Finding Guide

Blocked Blades and Drain Faults

Troubleshooting steps for 'BLOCKED BLADES' and 'BLOCKED DRAIN' error messages.

Water Level and Deodoriser Faults

Troubleshooting for 'REFILLING WATER', 'LOW WATER', and 'REFILL DEODORISER' messages.

Power Fail Error Troubleshooting

Guidance for resolving 'POWER FAIL' errors by checking electrical supply.

Hopper Full Error Troubleshooting

Troubleshooting steps for 'HOPPER FULL' errors related to drain blockage.

Lid Cannot Open Error Troubleshooting

Steps to resolve 'LID CANNOT OPEN' errors by checking obstructions and sensors.

Lid Cannot Close Error Troubleshooting

Steps to resolve 'LID CANNOT CLOSE' errors by checking obstructions and sensors.

Drain Valve Error Troubleshooting

Troubleshooting for 'DRAIN VALVE' errors indicating improper valve closure.

Lid Seal Error Troubleshooting

Troubleshooting for 'LID SEAL' errors related to improper lid seal inflation.

Lid Error Call Engineer Troubleshooting

Guidance for 'LID ERROR CALL ENGINEER' messages indicating lid operational issues.

Water Leaking Troubleshooting

Steps to diagnose and resolve water leaks from various parts of the machine.

Lid Movement Issues

Troubleshooting steps for when the lid fails to move due to sensor or motor issues.