DGT / DGT60 / DGTQ / DGTP
33
6.2 RS232 or COM2 SERIAL PORT
It is bi-directional (full duplex) and uses an RS232 for transmitting data; it is mainly used to connect to printers,
computers and PLCs. The transmission speed may be selected in the SET UP among these: 1200, 2400, 4800,
9600, 19200, 38400, 57600,115200 Baud.
Connections from LP542S, DP24, DP190 printer to indicator:
DP24/LP542S DP190 | INDICATOR CABLE
9pin (female) Terminal Board | STANDARD
-----------------------------------------------------------------------------------------------------------------------------------------
GND 5 GND | GND Grey
CTS 8 BU | RX Brown
RX 3 RX | TX Pink
Please find below the connection between the TPR printer and the indicator:
TPR | INDICATOR STANDARD
Terminal board | CABLE
-------------------------------------------------------------------------------
GND | GND Black
RTS | RX Yellow
RX | TX Grey
| Blue (not connected)
Please find below the connection in RS232 between the PC and the indicator:
PC PC INDICATOR STANDARD
9pin 25pin CABLE
(male) (male)
------------------------------------------------------------------------------------------------------------------------
GND 5 7 GND Grey
TX 3 2 RX Yellow
RX 2 3 TX Pink
Please find below the connection in RS232 for the DGT4/DGTQ/DGT60/DGTP configured as a repeater:
TRANSMITTER | DGT4 | DGTQ | DGT60 | DGTP |
-------------------------------------------------------------------------------------------------------------------------------------
GND | GND 17 | GND 8 | GND 17 | GND 32 |
TX | RX 16 | RX2 7 | RX 16 | RX 30 |
Below is shown the connection in RS232 between the GLH60R WEIGHT REPEATER and the indicator:
GLH60R | INDICATOR STANDARD
Serial line | CABLE
------------------------------------------------------------------------------------------------------------------------
RX 2 | TX Pink
GND 4 | GND Grey