DGT / DGT60 / DGTQ / DGTP
47
LEGEND
[CC] e <II>= instrument code, e.g.. 00 (only with RS485 protocol).
<CR LF>= Carriage Return + Line Feed (ASCII characters 13 and 10).
SERIAL ERRORS
Upon each serial command received the instrument transmits a response which may be a response to a command
(see the command description) or the indication of the command error:
ERR01<CR LF> it is shown when a correct command is transmitted from the PC to the indicator however it is
followed by letters inserted involuntarily (I.E.: READF TARES…).
ERR02<CR LF> it is shown when a correct command is transmitted from the PC to the indicator, but containing
wrong data.
ERR03<CR LF> it is shown when a non allowed command is transmitted. It may be a command not used in the
selected functioning mode or the command reaches the indicator in the instant in which the keyboard buffer is
already occupied by another command.
ERR04<CR LF> it is shown when an inexistent command is transmitted.