6
Trouble shooting
Failures
Cause
Solutions
1. Power indicator is
not
on and unit not heating
No Power to
machine.
1. Check power supply
2.heating indicator is on
but the temperature
dose
not rise
1.connection of the
electric
heating tube is loose
1.fasten the two terminals
between the electric heating
tube and the screw
2.replace the electric heating
tube
3.power indicator is on
but the setting
temperature
will not rise
1.temperature
controller damaged
1.replace the temperature
controller
4.temperature
controller is normal but
indicator is not on
1.indicator damaged
1.replace indicator