OMG100N1.17 G100 Range
Page 8 LANDTEC North America, Inc., DBA VIASENSOR
3.0 G100 Range Optional Products and Accessories
3.1 Optional Products
The G100 analyzer range has a number of optional products for purchase which enhance
the usability and enable further analysis of data and reading information.
Note: For further information, please contact Sales at VIASENSOR Toll Free
(855) VIASENSOR, + 1 (909) 783-9472 or email Sales@viasensor.com.
3.1.1 Analyzer Data Manager (Optional)
Analyzer Data Manager enables the user to maximise the operation of the incubator
analyzer. Instrument readings and event log data may be downloaded to a PC for further
analysis and exported to other applications such as MS Excel. It enables direct
communication with the unit, features a simple download facility and is fully compatible
with the latest Microsoft operating systems.
3.1.1.1 Event Log
The G100 instruments incorporate the facility to log significant events via the ‘Event Log’.
This can be used as an aid to monitoring the use of the instrument. It can also be used as
a diagnostic tool if there is a problem with the instrument.
The event log can only be viewed via the optional Analyzer Data Manager software. It
cannot be viewed on the analyzer screen. Applicable events are stored in the event log
automatically. No user intervention is required.
The event log can hold approximately 270 events. If the log becomes full then it begins
to over-write the older events. This can be identified by the index field which starts from
event number 1. The log is cleared when the instrument is reset.
Note: Please refer to section ‘12.0 Event Log’ of this operating manual for further
information.
3.1.2 Temperature Probe Reading (Optional)
The G100 range of instruments has the facility to read and display two temperature
readings via optional temperature probes. When a temperature probe is fitted to one of
the two temperature ports on the top of the instrument, the display will automatically
show the current reading and a temperature probe icon will be displayed.
The display can also be changed to show a T
1
T
2
calculation by pressing the appropriate
soft-key. The current mode of operation can be identified by normal or inverse status of
the soft-key, where inverse indicates that the option is active.
Note: The T
1
T
2
result is not stored as part of the reading.
The operator can also choose to display the reading in either Fahrenheit or Centigrade
using the temperature option accessed from the ‘Settings’ menu.