29
If problems still exist, perform the following:
1. Checkallcableconnectionstoensuretherearenoloosewiresorshort
circuits or incorrect connections.
2. Remove power.
3. ConnectthecommunicationcabletotheproblemMicroLYNXonly.
4. SetalladdressswitchesontheproblemMicroLYNXtoOFF.
5. Apply power.
6. SettheMicroLYNXtosinglemode.
Input: *PARTY=0
Output: (TheMicroLYNXwillechotheaddressto
which it is currently set.)
 TheMicroLYNXisnowinsinglemodeandanaddressisnotrequired.
7. Input: IP[Ctrl-J]
8. Input: SAVE[Ctrl-J]
9. Input: [Ctrl-C]
(Or cyclethepowerbyremovingpower,waitingfortheLEDtogoout,then
reapplying power.)
Output: Programcopyright1996-2000by:
Intelligent Motion Systems, Inc.
Marlborough,CT06447
VER=1.5000SER=xxxxxxx
TheMicroLYNXshouldsendthesign-onmessage.Atthispoint,theHost
andPartyagshavebeenreset,theaddresshasbeenresetto!andno
address is required to communicate with this controller.
10.Startoverwitheitherthehardwaremethodorthesoftwaremethodfor
setting the address. The procedures begin on page 25.
Setup for Multipump Operation