EasyManua.ls Logo

Victor 98A - Page 24

Victor 98A
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 24 -
Deta
Deta
Deta
Deta
iled
iled
iled
iled
Acc
Acc
Acc
Acc
urac
urac
urac
urac
y
y
y
y
Spe
Spe
Spe
Spe
cific
cific
cific
cific
atio
atio
atio
atio
ns
ns
ns
ns
All the
specul ations
apply
to
+18
to
+28
,
10 %
to
70%R H
unless stated
other wise.
All specul
ations assum
e a 5- minut
e warm
- up period .
Stand ard
specul ation
is valid
for one
year.
Accur acy
specifications are given as: ± ([% of reading] + [number of least significant digits])
Note
Note
Note
Note
Counts refers
to
the number of increments
or
decrements of the least significant digit.
DC
DC
DC
DC
Voltage
Voltage
Voltage
Voltage
Measurement
Measurement
Measurement
Measurement
C
C
C
C
Voltage
Voltage
Voltage
Voltage
Measurement
Measurement
Measurement
Measurement
DC
DC
DC
DC
Current
Current
Current
Current
Measurement
Measurement
Measurement
Measurement
Range
Range
Range
Range
Resolution
Resolution
Resolution
Resolution
Accuracy
Accuracy
Accuracy
Accuracy
Remark
Remark
Remark
Remark
40.00mV
0.01 mV
0. 5 %+ 6
Measuring Impedance > 2.5G Ω
Overvoltage Protection 1000V
400.0mV
0.1 mV
0.2%+4
4.000V
0.001V
0.2%+4
Measuring Impedance(Standard Value)
10 M Ω < 100 p F
Common mode rejection ratio: 50Hz or 60Hz > 100dB
Normal mode rejection ratio 50Hz or 60Hz > 45dB
Overvoltage 1000 V
40.00V
0.01V
0.2%+4
400.0V
0.1V
0.2%+4
1000V
1V
0. 5 %+4
Range
Range
Range
Range
Resolution
Resolution
Resolution
Resolution
Accuracy
Accuracy
Accuracy
Accuracy
(40 400Hz)
Remark
Remark
Remark
Remark
400.0 mV
0.1 mV
1.0%+4
Specifications are valid from 5% to 100% of amplitude range
400mV is only confined to manual range
AC conversion: averaging converter
Measuring Impedance : 10M Ω ( Standard V alue) < 100pF
Common mode rejection ratio: 50Hz or 60Hz > 60dB
Overv oltage protection : 1 0 00 V
4.000 V
0.001 V
0.5%+4
40.00 V
0.01 V
0.5%+4
400.0 V
0.1 V
0.5%+4
750V
1V
0.5%+4
Range
Range
Range
Range
Frequency
Frequency
Frequency
Frequency
Accuracy
Accuracy
Accuracy
Accuracy
Remark
Remark
Remark
Remark
Function
Function
Function
Function
Ranges/Description
Ranges/Description
Ranges/Description
Ranges/Description
DC Voltage
0 to 1000V
AC Voltage , averaging converter
0 to 750V
Basic
Basic
Basic
Basic
Accuracy
Accuracy
Accuracy
Accuracy
DC Voltage 0.2%
AC V oltage 0.5 %
DC Current
0 to 10A(constant measurement shall be limited within 15s
and lo g
less than 15min)
AC Voltage, averaging converter
0 to 10A(constant measurement shall be limited within 15s
and lo g
less than 15min)
Resistance
0 to 40M
Capacitance
0 to100 µ F
Diodes
Open circuit Voltage 1.1V to1.6V
Short circuit Voltage less than 0.2mA(Typical Value)
Continuity
Beeps < 50 Ω
Open Circuit Voltage < 0.45V
Short Circuit Voltage 130 μ A typical value
TC(K Type)T est
-200 ° C to 950 ° C (-328 to 1472 )
RTD(Pt100 Type)T est
-200 ° C to 700 ° C (-328 to 1292 )
Frequency
0Hz to 100kHz
Reading Storage
Save mode
500
Log mode
1000
Comp mode
1000

Related product manuals