PROGRAMMING GUIDE
• Enter the ENGINEER’S CODE: rst time type six times 1 (111111
factory default) and press ENTER(the red LED will illuminate);
• Conrm ENGINEER’S CODE: re-type the same code again or
type a new code (4 to 8 digits) then press ENTER (melody);
• Enter the code (4 to 8 digits) to enable RELAY 1 then press
ENTER (melody);
• Enter the RELAY 1 operation time (2 digits 01 to 99, i.e. 05 = 5
seconds, 00 = latch) then press ENTER (melody);
• Enter the code (4 to 8 digits) to enable RELAY 2 then press
ENTER (melody);
• Enter the RELAY 2 operation time (2 digits 01 to 99, i.e. 05 = 5
seconds, 00 = latch) then press ENTER (melody);
• Enter the code (4 to 8 digits) to enable RELAY 3 then press
ENTER (melody);
• Enter the RELAY 3 operation time (2 digits 01 to 99, i.e. 05 = 5
seconds, 00 = latch) then press ENTER (melody);
• The system is ready to use (the red LED will switch OFF).
PROGRAMMING NOTES
• Pressing the ENTER button twice during the programming
process, without changing any parameters, will exit from the
programming menu.
• When entering a relay code it must be dierent from the
ENGINEER'S CODE.
• To latch the relay type in the access code then press ENTER
to conrm. To unlatch the relay type in the same access code
again then press CLEAR to conrm.
RETURN SYSTEM TO PRESET ENGINEER’S FACTORY CODE
• Turn OFF the power to the codelock;
• Keep the ENTER button pressed while the power is turned
back ON;
• Release the ENTER button;
• The ENGINEER’s CODE is now reset back to 6x1 (“111111”).
ENTER THE
“ENGINEER’S CODE”
CONFIRM
OR CHANGE
“ENGINEER’S CODE”
ENTER
“ACCESS 1 CODE”
ENTER
“ACCESS 1 TIME”
ENTER
“ACCESS 2 CODE”
ENTER
“ACCESS 2 TIME”
SYSTEM
READY TO USE
ENTER
“ACCESS 3 CODE”
ENTER
“ACCESS 3 TIME”
Press ENTER
(red LED ON)
Press ENTER
(melody)
Press ENTER
(melody)
Press ENTER
(melody)
Press ENTER
(melody)
Press 1 six times
“111111”
(factory default)
Press 1 six times
“111111” again or
type new engineer’s
code (4 to 8 digits)
Type code to enable
relay 1 (4 to 8 digits)
Type code to enable
relay 2 (4 to 8 digits)
Two digits (01 to 99)
i.e. 05 = 5 seconds,
00 = latching
Two digits (01 to 99)
i.e. 05 = 5 seconds,
00 = latching
red LED OFF
Press ENTER
(melody)
Type code to enable
relay 3 (4 to 8 digits)
Two digits (01 to 99)
i.e. 05 = 5 seconds,
00 = latching
Press ENTER
(melody)
Press ENTER
(melody)
TERMINAL CONNECTIONS TECHNICAL SPECIFICATION
Connection Description Working voltage: 12V - 24Vac/dc +/- 10%
+ 12-24V AC or DC power input Current consumption: 20mA (standby); 70mA (max.)
- 0V power input Number of relays: 3, RLY1, RLY2 & RLY3 (C, NC and NO)
C1 Relay 1 common connection
Relay contacts:
3A @ 4Vac⁄dc (max)
Relay current ⁄ voltage: 3A @ 24Vac/dc (max.)
NO1 Relay 1 normally open connection Push to exit inputs: 2, SW1 and SW2 (switched 0V)
NC1 Relay 1 normally closed connection Back EMF protection: Yes, 3x MOV jumpers
C2 Relay 2 common connection Number of codes: 3 codes (1 code per relay)
NO2 Relay 2 normally open connection Programming: Via keypad
NC2 Relay 2 normally closed connection Working Temperature: -10 +50
o
C
C3 Relay 3 common connection
NO3 Relay 3 normally open connection
NC3 Relay 3 normally closed connection
SW1 Switched 0V PTE input to trigger relay 1
SW2 Switched 0V PTE input to trigger relay 2