EasyManua.ls Logo

Videx GSM Lite 4000 Series - Programming Guide; Return System to Preset Engineers Factory Code; Technical Specification

Videx GSM Lite 4000 Series
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
66250756-EN - V2.1 - 05/11/19
- 14 -
4000 Series GSM Lite Audio Intercom - Technical Manual
4000 Series GSM Lite Audio Intercom
Art. 4901 Technical Information
PROGRAMMING GUIDE
• Enter the ENGINEER’S CODE: rst time type six times 1 (111111
factory default) and press ENTER(the red LED will illuminate);
• Conrm ENGINEER’S CODE: re-type the same code again or
type a new code (4 to 8 digits) then press ENTER (melody);
Enter the code (4 to 8 digits) to enable RELAY 1 then press
ENTER (melody);
• Enter the RELAY 1 operation time (2 digits 01 to 99, i.e. 05 = 5
seconds, 00 = latch) then press ENTER (melody);
Enter the code (4 to 8 digits) to enable RELAY 2 then press
ENTER (melody);
• Enter the RELAY 2 operation time (2 digits 01 to 99, i.e. 05 = 5
seconds, 00 = latch) then press ENTER (melody);
Enter the code (4 to 8 digits) to enable RELAY 3 then press
ENTER (melody);
• Enter the RELAY 3 operation time (2 digits 01 to 99, i.e. 05 = 5
seconds, 00 = latch) then press ENTER (melody);
The system is ready to use (the red LED will switch OFF).
PROGRAMMING NOTES
• Pressing the ENTER button twice during the programming
process, without changing any parameters, will exit from the
programming menu.
When entering a relay code it must be dierent from the
ENGINEER'S CODE.
To latch the relay type in the access code then press ENTER
to conrm. To unlatch the relay type in the same access code
again then press CLEAR to conrm.
RETURN SYSTEM TO PRESET ENGINEER’S FACTORY CODE
Turn OFF the power to the codelock;
• Keep the ENTER button pressed while the power is turned
back ON;
• Release the ENTER button;
• The ENGINEER’s CODE is now reset back to 6x1 (“111111”).
ENTER THE
“ENGINEER’S CODE”
CONFIRM
OR CHANGE
“ENGINEER’S CODE”
ENTER
ACCESS 1 CODE”
ENTER
ACCESS 1 TIME”
ENTER
ACCESS 2 CODE”
ENTER
ACCESS 2 TIME”
SYSTEM
READY TO USE
ENTER
ACCESS 3 CODE”
ENTER
ACCESS 3 TIME”
Press ENTER
(red LED ON)
Press ENTER
(melody)
Press ENTER
(melody)
Press ENTER
(melody)
Press ENTER
(melody)
Press 1 six times
“111111”
(factory default)
Press 1 six times
“111111” again or
type new engineers
code (4 to 8 digits)
Type code to enable
relay 1 (4 to 8 digits)
Type code to enable
relay 2 (4 to 8 digits)
Two digits (01 to 99)
i.e. 05 = 5 seconds,
00 = latching
Two digits (01 to 99)
i.e. 05 = 5 seconds,
00 = latching
red LED OFF
Press ENTER
(melody)
Type code to enable
relay 3 (4 to 8 digits)
Two digits (01 to 99)
i.e. 05 = 5 seconds,
00 = latching
Press ENTER
(melody)
Press ENTER
(melody)
TERMINAL CONNECTIONS TECHNICAL SPECIFICATION
Connection Description Working voltage: 12V - 24Vac/dc +/- 10%
+ 12-24V AC or DC power input Current consumption: 20mA (standby); 70mA (max.)
- 0V power input Number of relays: 3, RLY1, RLY2 & RLY3 (C, NC and NO)
C1 Relay 1 common connection
Relay contacts:
3A @ 4Vac⁄dc (max)
Relay current ⁄ voltage: 3A @ 24Vac/dc (max.)
NO1 Relay 1 normally open connection Push to exit inputs: 2, SW1 and SW2 (switched 0V)
NC1 Relay 1 normally closed connection Back EMF protection: Yes, 3x MOV jumpers
C2 Relay 2 common connection Number of codes: 3 codes (1 code per relay)
NO2 Relay 2 normally open connection Programming: Via keypad
NC2 Relay 2 normally closed connection Working Temperature: -10 +50
o
C
C3 Relay 3 common connection
NO3 Relay 3 normally open connection
NC3 Relay 3 normally closed connection
SW1 Switched 0V PTE input to trigger relay 1
SW2 Switched 0V PTE input to trigger relay 2

Related product manuals