TERMINAL CONNECTIONS
Connection Description
+ 12-24V AC or DC power input
- 0V power input
C1 Relay 1 common connection
Relay contacts:
3A@24Vac/dc
NO1 Relay 1 normally open connection
NC1 Relay 1 normally closed connection
C2 Relay 2 common connection
NO2 Relay 2 normally open connection
NC2 Relay 2 normally closed connection
SW1 Switched 0V input to trigger relay 1
SW2 Switched 0V input to trigger relay 2
TECHNICAL SPECIFICATION
Working Voltage : 12V - 24Vac/dc +/- 10%
Current (standby) : 20mA
Current (during operation) : 70mA (max.)
Dry Contact Relays : 2, relay 1 and relay 2, 3A @ 24Vac/dc (max.)
Relay Codes : 2 (one code per relay, 4 - 6 digits)
Push to Exit : 2, SW1 and SW2 (switched 0V across terminals SW1/- for relay 1 and SW2/- for relay 2)
Dimensions : 103mm (W) x 120mm (L) x 40mm (D)
Working Temp. : -10 +50
o
C
CONNECTING THE CODELOCK TO THE GSM INTERCOM
Follow the connections as shown in Fig.11 when connecting the VR4KCLM-1 codelock to the GSM intercom.
VR4800-10
CO2
CN3
CN1
USB
CN6
Wiegand
UIM-138 USB
VOLT FREE
RELAY CONTACTS
1
0V
+12Vdc
VR4800-10
CO2
CN3
CN1
USB
CN6
Wiegand
UIM-138 USB
0V
+12Vdc
FAIL SECURE
LOCK RELEASE
1
Fig. 11
  Remember to set the VR4KCLM-1 relay time to a shorter time than that of the GSM relay time (RLT).
for fail safe lock wiring move
lock wire from NO to NC