66250675-EN - V1.0 - 05/09/17
23
4000 Series Vandal Resistant GSM - Technical Manual
4000 Series Vandal Resistant GSM Audio Intercom with Proximity Facility
Wiring Diagrams
GSMVRK CONNECTIONS
Fig.18 shows the wiring connections for a GSMVRK-1 / GSMVRK-1S audio kit.
Fig. 18
CN3
CN1
USB
CN6
CN5
Art.150
GSM Unit for VR Panels
Antenna
Wiegand
Button
Harness
UIM-138 USB
VR4KGSM-0
VR4KGSM-1
VR4KGSM-2
VR4KGSM-3
CN1
FAIL SECURE
LOCK RELEASE
GSMVRKC CONNECTIONS
Fig.19 shows connections for a GSMVRKC-1 / GSMVRKC-1S audio kit (also see Fig.11 on page 16 for volt free connections and fail
secure lock wiring).
Fig. 19
VR4800-10
CO2
CN3
CN1
USB
CN6
CN5
Art.150
GSM Unit for VR Panels
Antenna
Wiegand
Button
Harness
UIM-138 USB
VR4KGSM-0
VR4KGSM-1
VR4KGSM-2
VR4KGSM-3
CN1
CN1
FAIL SAFE
LOCK RELEASE
4
  Remember to set the VR4KCLM-1 relay time to a shorter time than that of the GSM relay time (RLT).
for fail secure lock wiring move
lock wire from NC to NO.