VRVK/6256 Series ā6 wire Busā Vandal Resistant videokit
VRVK/6256 Series - Installation handbook
SETTINGS (DIP-SWITCH & JUMPERS)
4 WAY DIP-SWITCH
First two switches are used to set the speaker unit address: the
speaker unit address is required for camera recall operation on
2 or more entrance systems.
ON
1 32 4
Switches 1,2 Unit Address
OFF OFF 1
ON OFF 2
OFF ON 3
ON ON 4
ON
1 32 4
Switch 3 Conversation Time
OFF 60 seconds
ON 120 seconds
ON
1 32 4
Switch 4 Door opening time
(J2 = āLā position)
OFF 2 seconds
ON 6 seconds
JUMPERS J1, J2
J1
J2
J1 Position Call tone reassurance volume
Right High
Left Low
J1
J2
J2 Position Door open relay operating mode
Right Dry contacts
Left Capacitor discharge
HOW TO CONNECT ELECTRIC LOCK
The ādoor-openā relay can operate either as ādry contactā or ācapacitive dischargeā mode.
⢠In ādry contactā operation mode the relay works in a traditional way, a power supply or a power source is needed to operate the
lock (12-24Vac/dc 2A max), and activation lasts according to the door opening time programmed.
⢠In ācapacitive dischargeā operation mode the relayās contacts, when active, supply directly the lock (12Vac/dc 1A max) for a
moment. You donāt need a power supply for the lock and the door opening time programmed do not aī£ect the activation time.
A possibile deterioration of the mechanical performance of the electric lock, might cause the ācapacitive dischargeā malfunctioning
in time. In case the electric lock is used in very dusty environments or in peculiar climate conditions, we suggest to use the āopen
doorā relay in ādry contactsā mode.
12Vac/dc 1A Max
Fig. 3
Using capacitive discharge
12Vac 1.6A Max using Art.ī¢321
24Vac/dc 2A Max using other power supplies
Fig. 4
Using separate P.S.U.
Art.ī”VR4KAMK Speaker unit