Loading...
66250693-EN - V5.1 - 30/09/20
- 14 -
VRVK/6256 Series “6 wire Bus” Vandal Resistant videokit
VRVK/6256 Series - Installation handbook
PROGRAMMING
Enter the ENGINEER’S CODE: rst time type six times 1 (111111
factory preset) and press ENTER (The red LED will illuminate);
Conrm ENGINEER’S CODE (typing again the same) or
type the new code (4 to 8 digits) then press ENTER (Melo-
dy). Pressing twice the ENTER button without changing the
ENGINEER’S CODE, will exit from the programming;
Enter the code (4 to 8 digits) to enable RELAY 1 or re-enter the
existing code then press ENTER (Melody);
Enter the RELAY 1 operation time (2 digits 01 to 99 I.E. 05=5
seconds, 00= remain open time) or re-enter the existing time
then press ENTER (Melody);
Enter the code (4 to 8 digits) to enable RELAY 2 or re-enter the
existing code then press ENTER (Melody);
Enter the RELAY 2 operation time (2 digits 01 to 99 I.E. 05=5
seconds, 00= remain open time) or re-enter the existing time
then press ENTER (Melody);
Enter the code (4 to 8 digits) to enable RELAY 3 or re-enter the
existing code then press ENTER (Melody);
Enter the RELAY 3 operation time (2 digits 01 to 99 I.E. 05=5
seconds, 00= remain open time) or re-enter the existing time
then press ENTER (Melody);
The system is ready to use (the red LED will be o).
PROGRAMMING NOTES
After pressing enter following a command, press ENTER a fur-
ther twice to exit the programming menu.
RETURN SYSTEM TO PRESET ENGINEER’S FACTORY CODE
Turn o power to code lock;
Keep ENTER button pressed while turning the power back on;
Release ENTER button;
The engineer’s code is now set to 111111 (six times one).
OPERATION
Type in the programmed code and press ENTER;
If the code is correct, the green LED will illuminate for approx.
2 seconds and the relay relevant to the code will operate for
the programmed time;
If a wrong code is entered, a continuous melody will sound
for 4 or more seconds, according to the number of mistakes;
To switch o any relay while operating, type in the relevant
code then press the CLEAR button;
OPERATION NOTES
To operate relays together, set the same code for each relay;
If a wrong code is entered, the system will lock out for 5 seconds
which will increase each time a wrong code is entered. The sys-
tem will operate only when the correct code is entered.
CONNECTION TERMINALS SIGNALS
SW2 Relay 2 command signal (active low)
SW1 Relay 1 command signal (active low)
NC3 Relay 3 normally closed contact
Max
24Vac/dc
3A
NO3 Relay 3 normally open contact
C3 Relay 3 common contact
NC2 Relay 2 normally closed contact
NO2 Relay 2 normally open contact
C2 Relay 2 common contact
NC1 Relay 1 normally closed contact
NO1 Relay 1 normally open contact
C1 Relay 1 common contact
12/24Vac/dc power input
+
CLEANING OF THE PLATE
Use a clean and soft cloth. Use moderate warm water or non-ag-
gressive cleansers.
Do not use:
abrasive liquids;
chlorine-based liquids;
metal cleaning products.
TECHNICAL SPECIFICATION
Power Supply: 12/24 Vac/dc – 2VA
Power Consumption: Stand-by: 20mA
Operating: 70mA
Working Temperature: -10 +50° C
ENTER THE
"ENGINEER’S CODE"
CONFIRM
OR CHANGE
"ENGINEER’S CODE"
ENTER
"ACCESS 1 CODE"
ENTER
"ACCESS 2 CODE"
ENTER
"ACCESS 3 CODE"
ENTER
"ACCESS 1 TIME"
ENTER
"ACCESS 2 TIME"
ENTER
"ACCESS 3 TIME"
SYSTEM
READY TO USE
First time six times
1 111111” factory
preset
Type again six times
“1” or the new en-
gineer’s code 4 to 8
digits
Code to enable relay 1
4 to 8 digits
Code to enable relay 2
4 to 8 digits
Code to enable relay 3
4 to 8 digits
Two digits (01 to 99)
i.E. 05=5 Seconds
00= remain open
Two digits (01 to 99)
i.E. 05=5 Seconds
Two digits (01 to 99)
i.E. 05=5 Seconds
Red led will be o
Press Enter
(Red LED will
be ON)
Press Enter
(melody)
Press Enter
(melody)
Press Enter
(melody)
Press Enter
(melody)
Press Enter
(melody)
Press Enter
(melody)
Press Enter
(melody)
Art.VR4901 Digital codelock module

Other manuals for Videx VRVK Series

Related product manuals