Special operating programs and functions
Screed drying:
This function is activated by your contractor at the
control unit of the Viessmann appliance (if the Viess-
mann appliance supports this function). Your screed
is dried in line with a set time program (temperature/
time profile) suitable for the relevant building materi-
als. Your settings for room heating have no effect on
the duration of screed drying (max. 32 days). The
system no longer provides DHW heating. The
"Screed drying" function can be altered or switched
off by your contractor.
Control unit of the Viessmann appliance
External hook-up:
The operating program set at the control unit was
changed over by an external device, e.g. an EM-EA1
extension (DIO electronics module). The operating
program cannot be changed via the control unit or
remote control while the external hook-up is active.
Control unit of the Viessmann appliance
"Extended heating"/"Extend time phase once":
See page 23.
Procedure for setting a time program
The following explains how to enter the settings for a
time program. The specifics of the individual time pro-
grams can be found in the relevant chapters.
Time programs and time phases
In the time programs, you specify what your heating
system should do at what time. To do so, divide the
day into sections. These are called time phases. Dif-
ferent temperature levels are enabled within and out-
side these time phases.
You can set up a time program for the following functions:
Function Setting on the
Viessmann device
Function
Within the time phase Outside the time phase
Central heating
Remote control
Control unit of the
Viessmann appli-
ance
Your rooms are heated to stand-
ard room temperature or com-
fort room temperature.
Your rooms are heated to re-
duced room temperature.
DHW heating
Remote control
Control unit of the
Viessmann appli-
ance
DHW heating is switched on.
The water in the DHW cylinder
is heated to the set DHW tem-
perature.
Domestic hot water heating is
switched off.
Using the remote control
Operating programs for central heating and DHW… (cont.)