Initial Start-up and Service
8
Procedure (Overview)
Initial start-up steps
Service steps
I
1. Fill heating system with water Page 9................................................................................................................
I
2. Check power supply connection Page 11..............................................................................................................
I
3. Select language (if required) Page 12.....................................................................................................................
I
4. Heating contractor address input Page 12...........................................................................................................
I S
5. Select appropriate gas type Page 13......................................................................................................................
I S
6. Measure static pressure and running pressure Page 13.................................................................................
I S
7. How the Vitodens 200 boiler operates... Page 15............................................................................................
I S
8. Check CO
2
setting Page 16........................................................................................................................................
I S
9. Clock natural gas meter Page 17..............................................................................................................................
S
10. Check orifice size Page 17..........................................................................................................................................
I S
11. Check all primary and secondary circuit c onnections for leaks Page 18................................................
I S
12. Perform combustion analysis Page 18...................................................................................................................
I
13. Check venting system for leaks (circular air gap measurement) Page 18..............................................
S
14. Disassemble burner and check burner gasket Page 19..................................................................................
S
15. Visually check exterior of burner mesh assembly Page 19...........................................................................
S
16. Replace burner mesh assembly (if wire mesh is damaged) Page 19........................................................
S
17. Check and adjust ignition and ionization electrode Page 20........................................................................
S
18. Check condensate drain Page 20.............................................................................................................................
S
19. Check neutralization unit (if applicable) Page 21................................................................................................
S
20. Clean combustion chamber/heat exchanger surfaces, and mount burner Page 21...........................
I S
21. Check diaphragm expansion tank and system pressure Page 22...............................................................
I S
22. Check functioning of safety valves Page 22.......................................................................................................
I S
23. Check electrical connections Page 23....................................................................................................................
I S
24. Check gas pipes and fittings for leaks Page 23.................................................................................................
S
25. Measure ionization current Page 24........................................................................................................................
I
26. Verify programming unit system coding addresses Page 24.......................................................................
I
27. Check extension kit for heating circuit with mixing valve Page 25..........................................................
I
28. Check Dekamatik-HK Page 26....................................................................................................................................
5285 961 v1.3