VIKING TECHNICAL SUPPORT 1.800.908.0884
10
SPECIFICATIONS
SPECIFICATIONS
Max Gate Length 18 Feet *refer to chart
Max Gate Weight 2000 lbs *refer to chart
UL 325 Classication Class I, II, III, IV *refer to page 5
Duty Cycle 100%
Operating Voltage 24VDC
Main Power Source 120VAC / 240VAC Single Phase
Main Power Current 1.5A / 1.0A (each motor)
Main Power Frequency 50Hz / 60Hz
Main Power Fuse 4.0A Timed
Alternative Power 24VAC/VDC (60VA) or Solar
Accessory Power 24VDC (750mA)
Power Consumption - Idle 72mA
Motor Current Draw - Typical 3.0A
Operating Temperature -20°F (-28°C) to 131°F (55°C)
Opening Angle 135°
! IMPORTANT: Cable shall be shielded with drain wire.
Connect drain wire to chassis ground of both the Operator
and the ECU.
MOTOR CABLE LENGTH/GAUGE
40 Feet 16 AWG
60 Feet 14 AWG
80 Feet 12 AWG
120 Feet 10 AWG
More than 120 Feet Not Recommended
0
2
6
12
18
0
1
2¼
4
5¾
8⅛
0
4⅜
5⅞
12⅞
14⅜
18¾
0
18⅛
7½
15¾
Front
Bottom
15½
Big Box ECU
(OPTIONAL)
4x Ø 1"
0
2
6
10
14
16
0
1½
4½
6⅛
0
3⅜
4⅞
11⅞
13⅜
16¾
0
5¼
13½
15⅝
Front
Bottom
Standard ECU
4x Ø 1"
21”
41⅞”
Max. Stroke
6½”
4”
3”
Strain Relief
2000 lb
1000 lb
800 lb
2000 lb
1500 lb
1000 lb
800 lb
10’1 2’ 14’1 6’
Gate Weight/Length Relationship
10’ 12’ 16’ 18’
FT
LB
1500 lb