20
K40980 - K40981
EN
Thebasicfunctionsoftheoutdoorstationscanbeconguredwiththedipswitchesatthetopright:
dip 1: Switchforsettingtheoutdoorstationasthemasterorslave.Whensetto1(on):theoutdoorstationisconguredas
the“master”outdoorstation;ineverysystem,onlyoneoutdoorstationconguredas“master”isnecessary;theoutdoor
stationsuppliedintheone-familyandtwo-familykitsisconguredasthe“master”bydefault.Anyadditionaloutdoor
stationsmustbeconguredas"slave",withthevalue0(o󰀨).
Default value: 1
dip 2-3: PairofswitchestoconguretheoutdoorstationID;theoutdoorstationsuppliedintheone-familyandtwo-familykitsis
conguredasoutdoorstation“1”bydefault,bysettingthedipswitchestothevalue00(sw2→0,sw3→0).Anyadditional
outdoorstationsmustbeassignedtheID2(10:sw2→1,sw3→0),ID3(01:sw2→0,sw3→1)orID4(11:sw2→1,
sw3→1).
Default values: 00
dip 4-5: Pairofswitchestoconguretheuseofthepushbuttons:theoutdoorstationsuppliedintheone-familykitsiscongured
bydefaultfortheuseof1(one)pushbutton,usingthevalue00(sw4→0,sw5→0);theoutdoorstationsuppliedinthe
two-familykitsisconguredbydefaultfortheuseof2(two)pushbuttons,usingthevalue10(sw4→1,sw5→0);for
systemswith3or4apartments,setthevalue01(sw4→0,sw5→1).
Default values: 00 for one-family system; 10 for two-family system.
dip 6: Switchtoassigntheactivationofthelockpoweredoroftherelaytothedoorreleasebuttononthefrontoftheindoorunit
andtothelockreleasebuttonontheoutdoorstation.
Ifswitch6is“1”(ON),thedenedlockistherelay;ifswitch6is“0”(OFF),thedenedlockisthepoweredone.
Switch6isconguredto“OFF”bydefault,i.e.thepoweredlockisthedefaultlock.
Congurationdipswitch
(defaultsettingforone-familymaster
outdoorstation)
6
5
4
3
2
1
01
(OFF)(ON)