8
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
US
ER!MANUAL!
BRUS
H /PAD DRIVER CLEANING
CA
UTION!
It
is advisable to wear protective gloves when cleaning the brush/pad because there may be sharp debris.
1.
Remove the brush/pad as shown in “Machine Use” section.
2. Clean and wash the brush/pad with water and detergent.
3. Check the brush bristles for integrity and wear. If necessary, replace the brush.
4. Check the pad for wear. If necessary, replace the pad driver.
RE
COVERY TANK MAINTENANCE
CA
UTION!
It
is advisable to wear protective gloves when cleaning the tank and vacuum/suction assembly because there
may be sharp debris.
1. Mov
e the machine to the appointed draining area.
2. Turn off the main switch. (47)
3. Remove the recovery tank, (2) clean and rinse both solution/recovery tank, and drain out.
4. Remove vacuum gasket & filter. Clean and re-install.
5. Check the recovery tank lid gasket and the vacuum rubber connector (18) for wear. Replace if
necessary.
NOTE
The
gasket ring of recovery tank and the rubber connector between two tanks create vacuum
in the tank. If necessary, replace them.