D-303169 KP-160 PG2 User’s Guide  7 
 
Notes: 
1. Every 5 minutes the keyprox performs a communication test 
session with the control panel (i.e. "Supervision signal) to check 
the integrity and quality of the Radio link. If the keyprox does 
not report a supervision signal at least once within a predefined 
time, a “MISSING” trouble alert is initiated. Therefore, if you 
take the keyprox out of the protected premises, switch the 
Supervision OFF to avoid the trouble alert.  
2. For UL Listed product, set to “ON”. 
Define whether or not the keyprox will sound the exit and entry 
beeps or whether the keyprox will sound the beeps only when the 
system is armed AWAY and not when it is armed HOME. 
 
Option settings: ON; OFF (default) and OFF @ Home. 
Under trouble conditions, the panel sounder emits a series of 3 
short reminder beeps once per minute. Here you determine 
whether to enable or disable this reminder beeping or just disable 
it at night. The “night” hours are defined in the factory but are 
usually from 8 PM (20:00) until 7:00 AM. 
 
Option settings: ON; OFF (default) and OFF @ night. 
Note: For UL Listed product, set to “ON”. 
 
Define the volume level of the sounder.  
 
Option settings: Medium (default); Maximum and Minimum 
Note: For UL Listed product, the sounder cannot be used as the 
only annunciator for the system. 
 
Enabling the function will turn off the display if no key is pressed 
for more than several seconds. 
 
Options settings: Disabled (default) and Enabled. 
Notes: 
1)  When the "SCREEN SAVER" menu on the PowerMaster 
control panel is configured as "refresh by key", touching the 
right side of the screen on the KP-160 PG2 device will return 
the device to normal display (refer to the PowerMaster 
Installer Guide, section 3.5.6). 
2)  When the "SCREEN SAVER" menu on the PowerMaster 
control panel is configured as "refresh by code", touching the 
right side of the screen on the KP-160 PG2 device and then 
presenting the proximity tag to the tag reader will return the 
device to normal display (refer to the PowerMaster Installer 
Guide, section 3.5.6). 
Note: For UL Listed product, set to “Disabled”. 
 
Select the function of the (AUX) key   when pressed: 
Not used: No function assigned to AUX key. 
Status: Control panel displays and announces* the system status. 
Trouble Beeps 
BUTTON () 
Screen Saver 
Sounder Volume 
EXIT-ENTRY Beeps