Define whether the panel will sound the exit/entry warning beeps during exit and entry delays or 
not. An additional option is to mute the warning beeps only when the system is armed “HOME”.
 
Options: ON (default), OFF when home (default in USA) and OFF, and OFF exit home.
 
Note: When exit beeps are OFF, the happy (success) melody will still sound toward the end of 
an exit delay. 
The volume level of the exit / entry beeps can be modified by pressing the   button on 
the keypad to increase the volume, or by pressing the   button to decrease the volume.
51:PIEZO BEEPS 
With Partition enabled 
Define whether the panel will sound the exit/entry warning beeps during exit and entry delays or 
not. An additional option is to mute the warning beeps only when the system is armed “HOME”. 
The control panel’s display is: Def:P1  P2  P3  
The pushbuttons  ,  , and   provide selection of the corresponding partitions. 
Pressing each button repeatedly will toggle between each option.
 
Options:   (enable beeps), H (OFF when home) h (OFF exit home) and
 
 (disable beeps).
 
Notes:  
When exit beeps are OFF, the happy (success) melody will still sound toward the end of an 
exit delay.  
The volume level of the exit / entry beeps can be modified by pressing the   button on 
the keypad to increase the volume, or by pressing the   button to decrease the volume. 
 
 
52:TROUBLE BEEPS 
Under trouble conditions, the panel sounder emits a series of 3 short reminder beeps once per 
minute. Define whether to enable or disable this reminder beeping or just disable it at night. 
The “night” hours are defined in the factory but are usually from 8 PM (20:00) until 7:00 AM. 
 
 
Options: ON (default in USA); OFF at night (default) and OFF. 
Note: Audible trouble beeps to be enabled for UL Listed product. 
 
 
53:MEMORY PROMPT 
Define whether or not the user will receive "Memory" LCD indication that an alarm has been 
activated. By pressing the   button in standby mode, you can view details of the alarm 
memory. 
 
Options: ON (default) and OFF. 
Note: For UL installations, set to “ON”. 
 
 
54:LOW-BAT ACK 
You can activate or deactivate the "Low Battery Acknowledge" requirement from the user whose 
keyfob's battery is low. For further information, see PowerMaster User's Guide Chapter 5. 
 
Options: OFF (default) – acknowledge not needed; ON – acknowledge required. 
Note: For UL installations, Low Battery Acknowledge must be set to ”ON". 
 
 
55:BACK LIGHT 
Define whether the panel's back lighting will remain on at all times or will turn on only when a 
key is pressed and turn off within 10 seconds if no further keystrokes are sensed.  
 
Options: always ON and OFF after 10 sec (default).