5. PROGRAMMING 
54 
D-304762 PowerMaster-10/30 G2 Installer's Guide 
Option  Configuration Instructions
 
To program: 
Press  to enter the "PSTN UP/DOWNLOAD" sub menu and then select and configure 
each of the sub-menu options as shown below. When done, press   to return.
 
→
→→
→
Remote access 
Enable or disable the remote access to the system. If disabled, the system cannot be 
accessed remotely thereby inhibiting the Upload/Download and the Remote Control via 
PSTN or GSM analog communication channels (see Chapter 7 in the User's Guide).
 
 
Options: enabled (default); disabled.
 
→
→→
→
Mast. UL/DL code
 
Enter the 4-digit password (Master Installer download code) code that will allow the Master 
Installer to access the system remotely and upload/download data to the PowerMaster panel. 
 
Note: "0000" is not a valid code and must not be used.
 
→
→→
→
Inst. UL/DL code
 
Enter the 4-digit password (Installer download code) code that will allow the Installer to 
access the system from remote and upload or download data into the PowerMaster panel.
 
 
Notes: 
"0000" is not a valid code and must not be used. 
The installer can configure via UL/DL only the options he is authorized to configure from the 
control panel.  
 
→
→→
→
UL/DL modes 
Define whether the downloading/uploading can be performed in Disarm mode (state) only or 
in all modes (i.e. Away, Home & Disarm).
 
Options: in all modes (default) or in DISARM only.
 
→
→→
→
Up/Download tel# 
Enter the telephone number (up to 16 digits) of the UL/DL server. 
Note: Only for use with control panels monitored by compatible monitoring stations. Leave 
empty if not used.
 
 (Return) 
 
Configure the Upload/Download functionality via GPRS. The functionality is determined 
through a sub-menu of the "GPRS UP/DOWNLOAD" option as shown below. 
To program: 
Press  to enter the "GPRS UP/DOWNLOAD" sub menu and then select and configure 
each of the sub-menu options as shown below. When done, press   to return.
 
→
→→
→
 
Panel SIM Tel.# 
Previously known as 
"My SIM Tel.#" 
 
Enter the PowerMaster SIM card telephone number. The PowerManage server at the 
Monitoring Station sends an SMS message to this number for the panel to call back the 
PowerManage server via GPRS for initiating the uploading / downloading process.
 
Enter the SIM card telephone number of the panel's GSM module.
 
→
→→
→
 1st caller ID# 
→
→→
→
 2nd caller ID# 
 
Enter the "Caller ID" (i.e. telephone number) from which Monitoring Station #1 (C.S.1) / 
Monitoring Station #2 (C.S.2) calls the control panel for initiating the Up/Download process. 
If the sender's Caller ID matches with the "1
st
 caller ID#" / "2
nd
 caller ID#", the PowerMaster 
will call back the PowerManage server using "IP RCVR 1" / "IP RCVR 2" address as 
configured in Section 5.6.4, options 21 and 22.
 
 
Note: Caller ID#1/ID#2 must contain at least 6 digits otherwise the process will not work. 
 (Return)
 
 
5.6.8 Broadband
1, 2
 
Note: If the Broadband Module is not registered to the PowerMaster, the menu "7:BROADBAND" will not be displayed. 
In this section you can configure how to obtain an IP address, enter LAN parameters and reset broadband 
module/settings. 
04:COMMUNICATION 
 
⋅ ⋅ ⋅ 
 7:BROADBAND   
⋅ ⋅ ⋅ 
 MENU you wish   
          
1
 Broadband is not applicable for UL installations
 
2
 The name of the product is PowerLink3 IP Communicator