Additional 
wireless devices 
30 detectors, 8 keyfobs, 8 keypads, 4 sirens, 
4 repeaters, 8 proximity tags 
64 detectors, 32 keyfobs, 32 keypads, 8 
sirens, 4 repeaters , 32 proximity tags
Wireless Devices 
and peripherals 
Magnetic Contact: MC-302 PG2, MC-302E 
PG2  
Motion Detectors: Next PG2; Next K9 PG2, 
TOWER-20 PG2 (not UL listed), TOWER-
32AM PG2 (not UL listed), TOWER-32AM K9 
PG2 (not UL listed), TOWER-30AM PG2, 
TOWER-30AM K9 PG2, CLIP PG2 (not UL 
listed) 
PIR Camera Detectors: Next CAM PG2; 
Next CAM-K9 PG2 
Smoke Detector: SMD-426 PG2, SMD-427 
PG2  
GSM Module: GSM-350 PG2
 (optional)
 
Keyfob: KF-234 PG2, KF-235 PG2 (not UL 
listed) 
Keypad: KP-140 PG2/KP-141 PG2 (with 
proximity tag), KP-160 PG2  
Indoor Siren: SR-720 PG2 
Outdoor Siren: SR-730 PG2 
Repeater: RP-600 PG2 
Gas: GSD-441 PG2 (not UL listed), GSD-442 
PG2 (CO detector) 
Glass-break: GB-501 PG2 (not UL listed) 
Temperature: TMD-560 PG2  
Flood: FLD-550 PG2  
Shock: SD-304 PG2 (not UL listed) 
Note: UL requires that when using remote 
smoke/CO detectors and repeaters, each 
detector must be within range (STRONG) of 2 
repeaters at all times (for path redundancy – 
UL 985). 
Magnetic Contact: MC-302 PG2, MC-302E 
PG2  
Motion Detectors: Next PG2; Next K9 PG2, 
TOWER-20 PG2 (not UL listed), TOWER-
32AM PG2 (not UL listed), TOWER-32AM K9 
PG2 (not UL listed), TOWER-30AM PG2, 
TOWER-30AM K9 PG2, CLIP PG2 (not UL 
listed) 
PIR Camera Detectors: Next CAM PG2; 
Next CAM-K9 PG2 
Smoke Detector: SMD-426 PG2, SMD-427 
PG2  
GSM Module: GSM-350 PG2
 (optional)
 
Keyfob: KF-234 PG2, KF-235 PG2 (not UL 
listed) 
Keypad: KP-140 PG2/KP-141 PG2 (with 
proximity tag), KP-160 PG2 
Indoor Siren: SR-720 PG2 
Outdoor Siren: SR-730 PG2 
Repeater: RP-600 PG2 
Gas: GSD-441 PG2 (not UL listed), GSD-442 
PG2 (CO detector) 
Glass-break: GB-501 PG2 (not UL listed)
 
Temperature: TMD-560 PG2 
 
Flood: FLD-550 PG2  
Shock: SD-304 PG2 (not UL listed) 
Note: UL requires that when using remote 
smoke/CO detectors and repeaters, each 
detector must be within range (STRONG) of 2 
repeaters at all times (for path redundancy – 
UL 985).
APPENDIX B. Working with Partitions 
Your alarm system is equipped with an integrated partitioning feature that can divide your alarm system into three 
distinct areas identified as Partition 1 through 3. A partition can be armed or disarmed regardless of the status of the 
other partitions within the system. Partitioning can be used in installations where shared security systems are more 
practical, such as a home office or warehouse building. When partitioned, each zone, each user code and many of your 
system's features can be assigned to Partition 1 to 3. Each user code is assigned with the list of partitions it is allowed 
to control in order to limit access of users to certain partitions. 
When partitioning is enabled, menu displays are changed to incorporate the partition feature and also each device, user, 
and proximity tag has additional partitions menu, where it is assigned to certain partitions and excluded from others.