USER SETTINGS 
DE5468U  25 
used to temporarily remove from service faulty zones that 
require repair work. Fire and temperature zones can not 
be bypassed.  
Remember – zone bypassing compromises security! 
Note:  Zones will be bypassed throughout one 
disarm-arm period only. Disarming the system after 
arming will suspend the entire bypassing scheme. 
B. Bypassing Procedure 
For PowerMax Pro with partition feature, you may set 
the bypass option according to the type of partition 
access permission. 
Having entered your user code
 successfully (see above 
- Entering the User Settings Menu), the display will read: 
SET BYPASS 
If at this point you click  , the number and 
state of the first zone / partition containing the first 
zone (in PowerMax Pro with partition feature) will be 
automatically displayed. Three states are then made 
possible: 
•  Open:  The zone is not secured - you can 
bypass the zone if you do not wish or know how 
to solve the problem right away. 
•  Bypassed:  The zone is presently bypassed 
(you bypassed it before but have not armed the 
system yet). 
•  Functional: If there is nothing wrong with the 
zone, its state is described as "Functional
".  
Let us assume that Zone 1 in partition 3 is "open" 
and you wish to bypass it, and the rest of the zones 
are functional. 
PRESS
 RESULTANT DISPLAY 
Z01 OPEN 
 
 
     (alternating)
 
 
 
KITCHEN 
 
<OK> TO BYPASS 
Z01 BYPASSED 
 
 
     (alternating)
 
 
 
KITCHEN 
Z02 FUNCTION 
     (alternating)
 
 
FRONT DOOR 
 
(If you wish 
to check the  
state of the 
next zone) 
 
 
SET BYPASS 
You can select any other item on the USER SETTINGS 
menu or quit programming by clicking 
. When <OK> 
TO EXIT is displayed - click 
 
button. 
At the end of the bypassing operation, BYPASS 
blinks:
 
READY BYPASS  or  NOT READY BYPASS 
This indication will persist as long as the system 
remains disarmed, and will disappear once the 
system is armed.  
Note: BYPASS will alternate in the display with other 
messages, such as: TRBL, MEM and MSG. 
C. "Unbypass" Procedure 
Suppose you wish to restore zone 22 of partition 3 
after having completed the bypassing scheme. Simply 
re-enter the SET BYPASS menu (see Bypassing 
Procedure above), and click 
 or   until 
the zone you wish to "unbypass” in the desired 
zone/partition is displayed. Refer to the following steps. 
PRESS
 RESULTANT DISPLAY 
Z22 BYPASSED 
 
 
     (alternating)
 
 
 LIVING ROOM 
<OFF> TO CLEAR 
 
Z22 FUNCTION 
     (alternating)
 
 
 
LIVING ROOM 
You may now click   and then select any other 
item on the USER SETTINGS menu, or click 
 
to quit programming. When <OK> TO EXIT appears 
- click 
. 
Reviewing the Bypassed Zone List 
Having entered your user code successfully (see 
above - Entering to the User Settings Menu), the display 
will read:  
PRESS
 RESULTANT DISPLAY 
SET BYPASS 
Enter user code 
SHOW BYPASS 
 
 
BYPASS LIST 
If at this point you click  , the number, state 
and name of the first bypassed zone will be displayed.  
You can now click 
 repeatedly to review all 
bypassed zones, in ascending numerical order. When 
done, clicking 
 will get you back to SHOW 
BYPASS and clicking 
 will get you back to 
<OK> TO EXIT. 
Recalling the Last Bypass Scheme 
Arming the alarm system with several zones in the 
bypassed state is in fact "partial arming". An 
identical partial arming may be repeated by recalling 
the last bypassing scheme (that was suspended and 
memorized upon disarming the system).