D-302541 1
POWERMAX PRO
Fully Supervised Wireless Alarm Control System
Installer Guide
TABLE OF CONTENTS
1. INTRODUCTION ....................................................... 3
2. SPECIFICATIONS..................................................... 3
2.1 General Data ...............................................................3
2.2 RF Section ...................................................................4
2.3 Electrical Data..............................................................4
2.4 Communication............................................................4
2.5 Physical Properties ......................................................4
3. INSTALLATION ......................................................... 4
3.1 Unpacking the Equipment............................................4
3.2 Supplying Power to the Unit.........................................4
3.3 System Planning & Programming................................4
3.4 Mounting......................................................................4
3.5 Back Unit Mounting and Wiring ...................................4
3.5.1 Phone Wiring ............................................................5
3.5.2 Zones and Sirens Wiring ..........................................6
3.5.3 Installing an Optional X-10 Siren ..............................6
3.5.4 Dual RS-232 Module Mounting.................................7
3.5.5 Audio Module Mounting ............................................7
3.5.6 Power Cable Connection ..........................................7
3.6 Front Unit Preparation .................................................8
3.6.1 Backup Battery Insertion...........................................8
3.6.2 X-10 Interface Module Connection................................8
3.6.3 Optional GSM/GPRS Module Mounting....................8
3.7 Final Closure................................................................9
4. PROGRAMMING..................................................... 10
4.1 INTRODUCTION .......................................................10
4.1.1 General Guidance...................................................10
4.1.2 Entering an Invalid Installer Code................................10
4.1.3 Installer’s Menu.......................................................10
4.1.4 Setting a New Installer Code ..................................10
4.1.5 Setting a New Installer Code in PowerMax Pro that
has 2 Installer Codes .......................................................10
4.2 ENROLLING WIRELESS SENSORS AND KEYFOB
TRANSMITTERS.............................................................11
4.2.1 General Guidance...................................................11
4.2.2 Enrolling Type.........................................................11
4.2.3 Enroll/Delete Sensors................................................11
4.2.4 Enroll/Delete Keyfob Transmitters.................................11
4.2.5 Enroll/Delete Wireless Commander...............................11
4.2.6 Enroll/Delete 2-Way Keypad....................................11
4.2.7 Enroll/Delete Wireless Siren ....................................11
4.2.8 Enroll/Delete Proximity Tags....................................11
4.3 DEFINING ZONE TYPES, NAMES, CHIME ZONES
& PARTITION .............................................................. 13
4.4 DEFINING CONTROL PANEL PARAMETERS.... 14
4.4.1 Preliminary Guidance..............................................14
4.4.2 Entry Delays 1&2 ......................................................14
4.4.3 Exit Delay................................................................14
4.4.4 Bell Time.................................................................14
4.4.5 Abort Time ..............................................................14
4.4.6 Alarm Cancel ..........................................................15
4.4.7 Quick Arm ...............................................................15
4.4.8 Bypass....................................................................15
4.4.9 Exit Mode................................................................15
4.4.10 Piezo Beeps..........................................................15
4.4.11 Trouble Beeps ......................................................15
4.4.12 Panic Alarm ..........................................................15
4.4.13 Swinger Stop ........................................................15
4.4.14 Cross Zoning ........................................................15
4.4.15 Supervision ...........................................................15
4.4.16 NOT READY.........................................................15
4.4.17 AUX Button A........................................................15
4.4.18 AUX Button B 2-W-KF.............................................16
4.4.19 Jam Detect............................................................16
4.4.20 Latchkey ...............................................................16
4.4.21 “Not Active” .......................................................... 16
4.4.22 Back Light ............................................................ 16
4.4.23 Duress.................................................................. 16
4.4.24 Piezo Siren........................................................... 16
4.4.25 Reset Option ........................................................ 16
4.4.26 Tamper Option ..................................................... 16
4.4.27 Siren On Line ....................................................... 16
4.4.28 Memory Prompt.................................................... 16
4.4.29 Disarm Option......................................................... 16
4.4.30 Bell/Rep. Option ................................................... 16
4.4.31 Low-Bat Ack ......................................................... 16
4.4.32 Screen Saver ....................................................... 17
4.4.33 Confirm Alarm ...................................................... 17
4.4.34 AC FAIL REP ....................................................... 17
4.4.36 User Permission................................................... 17
4.4.39 Key Zones Options (Optional).............................. 17
4.5 DEFINING COMMUNICATION PARAMETERS... 19
Preliminary Guidance...................................................... 19
4.5.1 PSTN / GSM (Fig. 4.5) ............................................ 19
4.5.2 GPRS / BB (Fig. 4.5).............................................. 19
4.5.3 C.S. Reporting (Fig. 4.5) ........................................ 20
4.5.4 Private Report (Fig. 4.5).......................................... 22
4.6 GSM Auto Detection.............................................. 25
4.7 PowerLink Auto Detection ..................................... 25
4.8 DEFINING OUTPUT PARAMETERS ................... 25
4.8.1 Preliminary Guidance............................................. 25
4.8.2 Define PGM............................................................ 25
4.8.3 Defining INT/STRB................................................. 25
4.8.4 X-10 GENERAL DEF................................................ 25
4.8.5 X-10 UNIT DEFINE................................................. 25
4.9 DEFINE VOICE ..................................................... 27
4.9.1 Record Speech ...................................................... 27
4.9.2 Speech Box Mode.................................................. 27
4.10 DIAGNOSTIC TEST............................................ 28
4.10.1 GPRS Communication Test ................................. 28
4.10.2 LAN Connection Test ........................................... 28
4.11 USER FUNCTIONS ............................................ 29
4.12 RETRIEVING FACTORY DEFAULTS ................ 29
4.13 SERIAL NUMBER ............................................... 29
4.14 CALLING UPLOAD/DOWNLOAD SERVER....... 29
4.15 ENABLING/DISABLING PARTITIONS ............... 30
4.16 WALK-TEST........................................................ 30
5. TESTING PROCEDURES ...................................... 30
5.1 Preparations.............................................................. 30
5.2 Diagnostic Test ......................................................... 31
5.3 Keyfob Transmitter Test............................................ 31
5.4 Appliance ON/OFF Test............................................ 31
5.5 Emergency Transmitter Test..................................... 31
6. MAINTENANCE ...................................................... 31
6.1 Dismounting the Control Panel.................................. 31
6.2 Replacing the Backup Battery................................... 31
6.3 Fuse .......................................................................... 31
6.4 Replacing/Relocating Detectors................................ 31
7. READING THE EVENT LOG .................................. 32
APPENDIX A. Detector Deployment & Transmitter
Assignments ................................................................ 33
A1. Detector Deployment Plan........................................ 33
A2. Keyfob Transmitter List............................................. 33
A3. Emergency Transmitter List...................................... 34
A4. Non-Alarm Transmitter List....................................... 34
APPENDIX B. X-10 Unit & PGM Output Assignments 34
APPENDIX C. Event Codes ........................................ 35
Contact ID Event Codes.................................................. 35

Table of Contents

Other manuals for Visonic POWERMAX PRO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic POWERMAX PRO and is the answer not in the manual?

Visonic POWERMAX PRO Specifications

General IconGeneral
Wireless Frequency868 MHz
CommunicationPSTN
Siren Output12V DC, 500mA
Remote ControlYes
Wireless RangeUp to 200 meters in open space
Operating Temperature0°C to 49°C
Humidity85% non-condensing