D-302541 35
APPENDIX C. Event Codes
Contact ID Event Codes
Code Definition Code Definition
101 Emergency 344 RF receiver jam detect
110 Fire 350 Communication
trouble
120 Panic 351 Telco fault
121 Duress 373 Fire detector trouble
122 Silent 380 Prob trbl
123 Audible 381 Loss of supervision
RF
131 Perimeter 383 Sensor tamper
132 Interior 384 RF low battery
134 Entry/Exit 393 Fire detector clean me
137 Tamper/CP 401 O/C by user
139 Burglary verified 403 Auto arm
151 Gas alarm 406 Cancel
152 Frzr alert 408 Quick arm
153 Frz alert 426 Door open event
154 Flood alarm 441 Armed home
158 Hot alert 454 Fail to close
159 Cold alert 455 Fail to arm
180 Gas trouble 456 Partial arm
301 AC loss 459 Recent close event
302 Low system battery 570 Bypass
311 Battery disconnect 602 Periodic test report
313 Engineer reset 607 Walk-test mode
321 Bell 641 Senior watch trouble
SIA Event Codes
Code Definition Code Definition
AR AC Restore GJ Gas trouble restore
AT AC Trouble HA Holdup Alarm (duress)
BA Burglary Alarm LR Phone Line Restore
BB Burglary Bypass LT Phone Line Trouble
BC Burglary Cancel OP Opening Report
BR Burglary Restore OT Fail to Arm
BT Burglary Trouble /
Jamming
PA Panic Alarm
BV Burglary Verified QA Emergency Alarm
BZ Missing Supervision RN Engineer Reset
CF Forced Closing RP Automatic Test
CI Fail to Close RX Manual Test
CL Closing Report RY Exit from Manual Test
CP Auto Arm TA Tamper Alarm
CR Recent Close TR Tamper Restore
EA Door Open WA Flood alarm
FA Fire Alarm WR Flood alarm restore
FT Fire Detector Clean XR Sensor Battery Restore
FJ Fire detector trouble XT Sensor Battery Trouble
FR Fire Restore YR System Battery Restore
GA Gas alarm YT System Battery Trouble /
Disconnection
GR Gas alarm restore YX Service Required
GT Gas trouble
4/2 Event Codes
Note: The report to central station is on the following zones: First wireless siren - zone 31, second wireless siren - zone 32,
GSM - zone 33, first 2-way keypad (MKP-150/151) - zone 35, second 2-way keypad (MKP-150/151) - zone 36.
Alarms
Zone # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
1
st
digit
4 4 4 4 444 4 4 4 4 4444555555555 5 5 5 5 5 5
2
nd
digit
1 2 3 4 567 8 9 A B CDEF123456789 A B C D E F
Restorals
Zone # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
1
st
digit
C C C C CCC C C C C CCCCDDDDDDDDD D D D D D D
2
nd
digit
1 2 3 4 567 8 9 A B CDEF123456789 A B C D E F
Supervisory trouble
Zone # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
1
st
digit
6 6 6 6 666 6 6 6 6 6666777777777 7 7 7 7
2
nd
digit
1 2 3 4 567 8 9 A B CDEF123456789 A B C D
Low Battery
Zone # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
1
st
digit
8 8 8 8 888 8 8 8 8 8888999999999 9 9 9 9
2
nd
digit
1 2 3 4 567 8 9 A B CDEF123456789 A B C D
Forced Arming – 8 users
User No. 1 2 3 4 5 6 7 8
1
st
digit A A A A A A A A
2
nd
digit 1 2 3 4 5 6 7 8
Zone Bypass
Zone # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
1
st
digit
A A A A AAA A A A A AAAABBBBBBBBB B B B B B B
2
nd
digit
1 2 3 4 567 8 9 A B CDEF123456789 A B C D E F