7. READING THE EVENT LOG
Up to 100 events can be stored in the event log. You can
access this log and review the events, one by one. The log
uses the first in, first out (FIFO) principle. If the event log
fills up completely (100 events), the oldest event is deleted
upon registration of each new event.
The
date and time of occurrence are memorized for each
event.
When reading the event log, events are shown in
chronological order - from the newest to the oldest. Access to
the event log is provided by clicking the asterisk
key
and not through the installer’s menu. Reading and erasing
process of the event log is shown in the next drawing.
Note: Up to 250 events can be stored in the event log via
the Upload / Download software application.
Oldest Event
Latest Event
LIST OF EVENTS
CODE _ _ _ _
(Enter 4-digit
installer code)
(*)
<OK TO EXIT
CLEAR EVENT LOG
<OFF> TO DELETE
(Return to normal
operation)
(**)
Figure 7 - Reading / Erasing the Event Log
* Event is displayed in 2 parts, for example, "Z13 alarm" then "09/02/00 3:37 P". The two displays will be shown
alternately until clicking
again to move to the next event or until the end of the event log (4 minutes).
** Applicable only if installer code is entered. Not applicable in European countries.

Table of Contents

Other manuals for Visonic POWERMAX PRO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic POWERMAX PRO and is the answer not in the manual?

Visonic POWERMAX PRO Specifications

General IconGeneral
Wireless Frequency868 MHz
CommunicationPSTN
Siren Output12V DC, 500mA
Remote ControlYes
Wireless RangeUp to 200 meters in open space
Operating Temperature0°C to 49°C
Humidity85% non-condensing

Related product manuals