EasyManua.ls Logo

Vitus Audio Reference Series - The Topology of the Volume Control; Connecting; Turning the RD-101 on and off

Default Icon
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Not following this procedure, may cause damage to any
of your products/speakers. Damage caused by not following
this procedure will invalidate the warranty.
2. CONNECTING
Turning the RD-101 on and off
RD-101 Owner’s manual | 11
1. GETTING STARTED
10 | RD-101 Owner’s manual
Always turn on the products beginning from the source:
Source pre-amplier power amplier
Always turn o your products in reverse order:
Power amplier pre-amplier Source
The topology of the volume control used in the RD-101 is very
dierent compared to the “standard”. The RD-101 uses a series of
xed resistor networks to control the volume. Relays are used to
switch between the resistor networks. Across all volume steps, a
xed resistor is in series with the signal path. This gives the best
performance possible. When you change volume, a dierent
number of shunt resistors are used.
The topology of the volume control
To prevent pop in the output, we have chosen to rst add the new
shunt resistors, and then wait a short time, before removing the
unused shunt resistors at the new volume step. This will give a minor
fall in volume before settling at the new volume step. It takes very
little time to get used to this type of operation of the volume, and
it will give you superior sound quality over the traditional digital
and analogue potentiometers.

Related product manuals