Customization
Vivint Element CT200 Operation Guide
1. From the Home screen, press and hold the SIDE button for three
(3) seconds.
2. Press DOWN to highlight Info, then press the SIDE button.
Information about the Thermostat displays.
3. Press UP or DOWN to scroll through the available information.
Installer
Installer settings control the following Thermostat functions:
EQUIPMENT: heating, cooling, humidity control, and fan behavior
COMFORT: swing, dierential, and other settings
NETWORK: the Thermostat’s connection to a Z-Wave Network
TESTING: the Thermostat’s connection to your equipment
RESET: resetting the Thermostat’s software to factory default
EQUIPMENT
The Equipment settings menu is
typically used during installation
of the Thermostat. The options in
this menu enable you to set the
heating, cooling, humidity control,
and fan equipment behavior.
See the Installation Guide’s Setup section for information on setting
those options.
COMFORT
Comfort settings enable you to control:
CALIBRATION: Osets the unit’s temperature display
CYCLING: This feature enables you to set the acceptable variance
in temperature between the Thermostat’s setting and the
current room temperature before the heating or cooling
system will turn on. The Cycling range can be from 0.5 to
4.0F (.25 to 2C). For example, if Cycling is set to 2.0°F and
the Thermostat is set to 70°F target temperature, the heat
cycle will start when the room temperature drops to 68°F.
Similarly, the cooling system will start when the room
temperature increases to 72°F. The HVAC runs until the
room reaches the target temperature, and then shuts o.
!
WARNING
Be sure to turn the thermostat
operating mode to OFF before
changing HVAC setup
39