Overview of the thermostat's physical interface and buttons.
Guidance on selecting the optimal placement for the thermostat.
Instructions for securing the mounting plate and passing wires through it.
Steps for preparing and labeling wires for connection to the thermostat.
Guidance on connecting the prepared wires to the correct terminals.
Explains the options for powering the thermostat, including 24VAC and batteries.
Visual representations of various HVAC system wiring configurations for the thermostat.
Sequential instructions for wiring common HVAC system types.
Procedure for adding the thermostat to the Z-Wave network via the panel.
Method for automatically adding Z-Wave devices using QR codes.
Configuration steps for the thermostat's humidity control features.
Configuration steps for the thermostat's heating system type and stages.
Configuration steps for the thermostat's cooling system type and stages.
How to choose the operational mode for the thermostat (Heat, Cool, etc.).
Procedures for testing the heating and cooling functions of the installed thermostat.
Description of the thermostat's primary display and its elements.
How to change the thermostat's operating mode (Heat, Cool, etc.).
How to set the fan operation mode (e.g., auto, on, timed).
How to view external temperature and internal humidity readings.
Overview of accessing and navigating the thermostat's settings menu.
Information on Z-Wave network connection and program control.
Explanation of the minimum cycle time feature for compressor longevity.
Accessing and adjusting user-configurable thermostat settings.
Detailed settings for humidity control if the system supports it.
Displays device information such as power source, network status, and software version.
Running diagnostic tests on heating and cooling equipment connections.
Accessing advanced settings typically configured during installation.
Configuring heating, cooling, and humidity system types and stages.
Configuration options for cooling system type and stages.
Settings for connecting or disconnecting the thermostat from the Z-Wave network.
Adjusting the thermostat's temperature sensor offset.
Setting the temperature differential for system on/off cycles.
Configuring temperature differentials for multi-stage HVAC system operation.
Restoring thermostat settings to factory defaults and disconnecting from the network.
Handling low battery warnings and replacing batteries.
Important compliance and safety information regarding radio frequency emissions.
Details on RF radiation exposure limits and compliance requirements.
Compatibility information and usage limitations for the thermostat.
| Power | 24 VAC |
|---|---|
| Operating Temperature | 32°F to 104°F (0°C to 40°C) |
| Operating Humidity | 5% to 95% (non-condensing) |
| Temperature Accuracy | ±1°F (±0.5°C) |
| Compatibility | Vivint Smart Home System |
| Connectivity | Z-Wave |
| Control | Mobile App |
| Energy Saving Features | Scheduling |
| Integration | Vivint Smart Home system, Google Assistant, Amazon Alexa |
| Voice Control | Works with Google Assistant and Amazon Alexa |