Group: status
NAME VALUE SECURITY
(get/set)
DESCRIPTION
di_i<0~(ndi-1)> <boolean> 1/7 0 => Inactive, normal
1 => Active, triggered
do_i<0~ndi-1)> <boolean> 1/7 0 => Inactive, normal
1 => Active, triggered
onlinenum_rtsp integer 6/7 current RTSP connection numbers
onlinenum_httppush integer 6/7 current HTTP push server connection numbers
Group: di_i<0~(ndi-1)> (capability.ndi > 0)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
normalstate high,
low
1/1 indicate whether open circuit or closed circuit
represents inactive status
Group: do_i<0~(ndo-1)> (capability.ndo > 0)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
normalstate open,
grounded
1/1 indicate whether open circuit or closed circuit
represents inactive status
Group: security
NAME VALUE SECURITY
(get/set)
DESCRIPTION
privilege_do view, operator,
admin
6/6 Indicate which privilege and above can control
digital output
privilege_camctrl view, operator,
admin
6/6 Indicate which privilege and above can control
PTZ
user_i0_name string[64] 6/7 User’s name of root
user_i<1~20>_name string[64] 6/7 User’s name
user_i0_pass password[64] 6/6 root’s password
user_i<1~20>_pass password[64] 7/6 User’s password
user_i0_privilege viewer,
operator,
admin
6/7 root’s privilege
user_i<1~20>_
privilege
viewer,
operator,
admin
6/6 User’s privilege.