R750EU5 - IE3 - TE4 - IE4 - ISE4
English          57       Ed.8 / 10-2012
GB
INFORMATION ABOUT FAILURES
TROUBLESHOOTING
The information below are provided to 
facilitate the identication and solution 
of possible anomalies and failures which 
may occur during operation. Some of 
these problems can be solved by the user, 
while others require specic technical 
skills or abilities, therefore they should be 
exclusively dealt with by qualied tech-
nicians with extensive experience in the 
specic sector of intervention.
Activation of a visual and/or acoustic 
signal indicates some form of malfun-
ction. In this case, turn the engine off 
immediately and consult the documen-
tation supplied by the manufacturer of 
the vehicle/device in which the engine 
is installed.
Problem Cause Remedy
 
 
 During the ignition phase the 
control board and the engine do 
not start.  
 
 Flat battery    Recharge or replace battery  
 Blown fuse    Replace fuse  
 The electric cables are 
disconnected or they do not 
guarantee continuity  
 Check the electric connections  
 Failure of engine revolution 
sensor  
 Replace the sensor 
Apply to an authorised workshop  
 
 
 The engine does not start  
 
 
 
 
 Presence of air in the fuel supply 
circuit  
 Carry out bleeding (See “Fuel 
supply circuit bleeding”)  
 Dirty or faulty injectors  
 Replace the injectors 
Apply to an authorised workshop  
 faulty fuel pressure regulation 
valve  
 Replace the valve  
Apply to an authorised workshop
 Failure of the start control  
 
 Replace the start control  
 Apply to an authorised workshop  
 water and/or impurities in the fuel   Apply to an authorised workshop  
 Clogged fuel lter  
 Replace lter (See “Fuel lter 
replacement.”)  
 
 The starter motor runs idle  
 
 Electromagnet failure  
 Check the starter motor  
 Apply to an authorised workshop