a) Operating elements of the software and the basic operation
N
A
B
C
DE
F
G
H
I
J
K
L
M
A Function tabs Switch the function of the window on the right-hand side between:
External timed program (External Timed Program)
Internal preset memory (Internal Preset Memory)
Data log (Data Log)
Setting (Setting)
B Data entry table The data entry eld for the external timed programming function.
The maximum number of actions is 20.
C Clear Table Clear all the data in the data entry table for the external timed
programming function.
D Run / Stop Run (Run) / Stop (Stop) the external timed program according to
the values in the data entry table.
E Running Cycle The number of cycle that the timed program is going to run. The
value is valid from 0 – 999, where 0 means an innite cycle.
F Table Description A text eld for entering a table description.

Table of Contents