Maximum input values, overload protection
Voltage measurement : 1000VDC or 750VACrms
Current measurement : 20A AC/DC in the A-range, for max.
10s with a subsequent cool-down
phase of min. 15 minutes, max.
250VDC/VACrms, overload protec-
tion: super-quick-acting 10A-250V
fuse, type: high energy
400mA AC/DC in the mA-range, for
max. 250VDC/VACrms, overload pro-
tection:
super-quick-acting 0.5A-250V fuse
type: high energy
Resistance measurement : overload protection 600V DC/ACrms
Diode test : overload protection 600V DC/ACrms
Capacity measurement : overload protection 600V DC/ACrms
Frequency measurement : overload protection 600V DC/ACrms
Attention!
If the maximum permissible input values are excee-
ded, the measuring instrument will be damaged and
under unfavourable conditions the user's life will be
endangered seriously.