Power supply ........................................2 x battery type AA 1.5 V
Measuring category ..............................CAT III 500 V
Frequency range ..................................50 – 400 Hz
Operating temperature range ...............0 to +40 °C
Humidity ................................................< 80 % rF
Continuity test .......................................up to 40 Ω
Battery test ...........................................1.5 V/9 V
Safety ................................................... ceramic high-performance fuse Flink
6.35 x 32 mm (0.5 A/10 A) 500 V
Dimensions ...........................................150 x 102 x 54 mm (L x W x H)
Weight ..................................................approx. 261 g
Voltage DC 100mV
2/10/50/100/250/500 V
± 4 % Input impedance
20 kΩ/V 100 mV via
mA connection “10“
Voltage AC 10/50/250/500 V ± 5 %
Current
DC mA/A
0,05/0,5/5/10/50/100/500 mA
10 A
± 4 %
Current
AC mA
0,25/2,5/25/50/250/500 mA ± 5 %
Resistance x 1/ x 10/ x 100/ x 1K ± 4 %