Fault Code Register
AirFilterInd
Air filter sensor.
Air Filter Clogged.
Sensor failure.
AirInletTemp
Air Inlet Temperature /(Ambient Air Temp)/Intake Air System
Open circuit sensor signal.
Current above normal or short circuit to battery negative.
AmbAirTemp
Air Inlet Temperature /(Ambient Air Temp)/Intake Air System
Open circuit sensor signal
Current above normal or short circuit to battery negative
BattPotential Wrn
Battery voltage to engine control unit
Check belt tension. Refer to Drive belt, check and change.
Check battery fluid level. Refer to Battery, page 92.
BridgeStop
Bridge Emergency Stop, Enable
Electrical failure at Bridge Emergency Stop Switch
Bridge Emergency Stop Switch is missing.
Measurement resistors are missing.
Coolant Level
Low coolant level.
Check for coolant leakage.
Check coolant level. Refer to Coolant Level.
CalibrMemFail
Software corrupt.
CAN BB1
CAN communication failure.
CAN BB2
CAN communication failure.