ECUProgFail
Software corrupt.
EmeStopSwEng
Engine is emergency stopped.
Emergency stop switch in engine room is enabled.
EMSCutRelay
EMS Power Cut Relay.
Electrical failure in Shutdown Module (SDM)
Fls Throttle In
Engine speed demand to system lacking
Check Control Lever
FuelDelPress
Fuel pressure too low.
Check fuel level.
Check that the fuel filters are not blocked. Replace filters if necessary.
Refer to Engine Fuel Filter Replacement
Check for fuel leakage.
DEFPumpBlk
The Urea return flush function does not work.
Blocked AdBlue line or dosing unit.
DEFPurgValv
AdBlue revert valve.
Electrical failure.
GearOilPres
Reverse gear oil pressure too low.
Critical system fault Engine shuts down automatically.
Check the oil level. Refer to Reverse gear, ZF.
Check that the oil strainer is not blocked. Refer to Reverse gear MGX.
Contact a Volvo Penta workshop if the fault remains.
InjectorCyl#1
Injector fault.