- 97-
r16.02
Output power
Unit:0.1kw,output power will be negative in regen
state
-
●
r16.03
Power factor
-1.000~1.000
-
●
P16.04
Electricity meter zero
clearing
0:no function;1111:clear to zero
0
☆
P16.05
Energy saving control
0:disable
1:enable
0
★
P16.06
Energy saving voltage
limit
0%~50%(0% means Energy saving control
disable and more than 0% means Energy
saving controlenable
0%
☆
P16.07
Energy saving filter time
0.0~10.0s
2.0s
☆
Notice:P16.05 is invisible When energy saving enabled, the output
current can be reduced and thepower loss can be reduced when the
load is light.For example, the fan and pump is light oaded, most of the
inverters do not have this function, so we are more energy efficient.
Energy savings can be achieved when it is light loads or load changes
so slow