IR610 high performance vector control frequency inverter user manual Chapter 5 function code table
- 122 -
Modbus
response
characteristics
When the format of the received frame is a
write register, this parameter can be set to
reply to the host.
0: Reply to the host (standard Modbus
protocol)
1: Do not reply to the host (non-standard
Modbus protocol)
31 Group Canopen communication parameter
CANopen
communication
address
0:100k
1:125k
2:250k
3:500k
4:1M
Display the version number of the CANopen
card
0: Initialisation status
1: Disconnected
2: Connecting/Preparing-
3: Stopped
4: Operational status
5: Pre_operational
CANopen
receive error
count
The number of error frames received by
CANopen is not saved after power off
The number of frames sent by CANopen is
not saved after power off
The number of frames received by CANopen
is not saved after power off