24 561810 - 04.2021 - V1
INSTRUCTION MANUAL VOSS.FARMING POULTRY KIT
7 INSTALLATION AND INITIAL OPERATION
7.1 BEFORE INSTALLATION
Before you can mount the VOSS.farming Poultry Kit and connect it to the door, you
must observe the following points:
Find a suitable mounting location for the device. Take into account that during the
opening of the door, the load on the device is greater than its own weight. The
installation site must be protected from moisture, water and rain.
Make sure that the light sensor is not aected by extraneous light (e.g. articial light
from path lighting or from the window of a residential building).
The device is always mounted in an upright position with the cord outlet on the
bottom. The door must be mounted so that the cord comes out of the unit vertically.
The device must be mounted in such a way that the door is pulled straight upwards.
There should be a distance of 10-12 cm between the device and the open door:
Only use a door that meets the following criteria:
The door has a weight between 300g and 1500g.
The door moves vertically and is moved into a closed position by gravity.
The door is smooth-running. No great force is needed to open the door and
when the door is released it closes independently and reliably. Use a few drops
of oil if necessary. The pull cord can be routed unhindered from the door to the
unit without rubbing against foreign objects.
The guide rails of the door must be properly mounted so that the door closes
securely.
Info
You will nd suitable doors in our product range.