35
Display parameters, Language, Alarm settings, Printer
settings and PIN settings.
82 Meter factory parameter data error!
There is a fatal error within the factory set parameters of the
Meter. The unit will need to be replaced.
107 Illegal weight gradient! (Err.107) This error occurs if there is a severe calibration error. E.g. if
tare and full load are switched during parameter entry.
Check the calibration and correct the error(s).
111 CAN Communication error! (Err.111) There is a communication problem between the Meter and
the Smart boxes. Check wiring between Meter and Smart
boxes. Especially cables between truck and trailer with
connectors should be checked.
210 File data error! (Err.210) Errors 210 to 215 could occur during Smart box set-up
restore procedure showing a file handling error. It indicates
some type of file memory problem. Try restarting the Meter.
If the problem persists the unit will need to be replaced.
This error only affects the backup and restore of Smart
boxes. Weighing is not affected.
File open error! (Err.211)
File open/create error! (Err.212)
File close error! (Err.213)
File write error! (Err.214)
File read error! (Err.215)