16 Technical data
39 100_0102_td_0004.fm
The following points must be observed:
Only use permitted extension cables.
Refer to nameplate for details of type designation and voltage of this machine.
Refer to the following table for the required cross-section area.
Machine type Voltage
[V]
Extension
[m] (ft)
Cross-section area of
cable
[mm
2
]
AR34/3/230 v 0...400 3~ <
150 (492.1) 1.5
AR34/3/400 400 3~ <
150 (492.1) 1.5
AR34/6/042 42 3~ <
14 (45.9) 1.5
<
23 (75.5) 2.5
<
35 (114.8) 4
<
52 (170.6) 6
AR34/6/250 250 3~ <
150 (492.1) 1.5
Machine type Voltage
[V]
Extension
[m] (ft)
Cross-section area of
cable
[AWG]
AR34/3/230 v 0...400 3~ <
150 (492.1) 16
AR34/3/400 400 3~ <
150 (492.1) 16
AR34/6/042 042 3~ <
12 (39.4) 16
<
19 (62.3) 14
<
30 (98.4) 12
<
46 (150.9) 10
AR34/6/250 250 3~ <
150 (492.1) 16

Table of Contents