19 Technical data
100_0102_td_0006.fm 50
19.2.1 Extension cable
Designation Unit AR64/6/250 AR64/9/042
Item no. 5100004223 5100004021
Rated current A 3,30 16,00
Rated voltage V 250 42
Rated frequency Hz 200 150
Rated output kW 1,25 1,10
Phases ~ 3 3
Centrifugal force kN 10,36 9,88
Vibrations rpm 6,000 9,000
Hz 100 150
Centrifugal force max. kN 19,03 18,14
Length mm (in) 245 (9.6) 245 (9.6)
Width mm (in) 150 (5.9) 150 (5.9)
Height mm (in) 188 (7.4) 188 (7.4)
Weight kg (lb) 13.80 (30.4) 12.90 (28.4)
Motor type Induction motor
Class rating l lll
Protection class IP65 IP65
Storage temperature range °C (°F) -30 – +70
(-22 – +158)
-30 – +70
(-22 – +158)
Operating temperature
range
°C (°F) -10 – +50
(+14 – +122)
-10 – +50
(+14 – +122)
Housing external
temperature
°C (°F) 80 (176) 80 (176)
Sound pressure level L
pA
*
dB(A) 76 76
Standard
EN ISO 11201, EN 12649
*
Only guaranteed with a Wacker Neuson power cable.
**
Measured at distance of 1 m (3.2 ft).
WARNING
Warning about voltage.
Serious injuries from electric shock.
Check power cable and extension cable for signs of damage.
Only use extension cables for which grounded conductors are connected to the plug
and the coupling (only for machines of protection class I + III, see chapter "Technical
data").